background image

 

  

 

 

12 

   

 

Ordercode: 30751 

Sunstrip Active MKII 110V 

Control Panel 

 

 

A)  LED display 
B)  Mode button 
C)  Menu button 
D)  Up button 
E)   Down button 

 
 

Fig. 04 

 

 

 

Control Mode 

The fixtures are individually addressed on a data-link and connected to the controller.  
The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, 
the controller will display the saved DMX address, next time.) 
 

DMX Addressing 

The control panel on the back side of the device allows you to assign DMX fixture addresses, which is the 
first channel with which the Sunstrip will respond to the controller. 
Please note, when you use the controller, the unit has 10 channels. 
When using multiple Sunstrips, make sure you set the DMX addresses right. 
Therefore, the DMX address of the first Sunstrip should be 1(A001); the DMX address of the second Sunstrip 
should be 1+10=11 (A011); the DMX address of the third Sunstrip should be 11+10=21 (A021), etc. Please, 
be sure that you do not have any overlapping channels in order to control each Sunstrip correctly. If two 
or more Sunstrips are addressed similarly, they will work similarly. 
 

Controlling: 

After having addressed all Sunstrips, you may now start operating these via your lighting controller. 
Note:
 After switching on, the Sunstrip will automatically detect whether DMX 512 data is received or not. 
If there is no data received at the DMX-input, the “LED“ on the control panel will not flash. 
If not, the problem may be: 

 

The XLR cable from the controller is not connected with the input of the Sunstrip. 

 

The controller is switched off or defective, the cable or connector is detective, or the signal wires are 
swapped in the input connector. 

 
Note: 
It is necessary to insert an XLR termination plug (with 120 Ohm) in the last fixture in order to ensure 
proper transmission on the DMX data link.  
 

 

Display Off after 10 seconds

 

 

When no button is pressed for 10 seconds, the display will turn off. 
To light up the display, you have to press the ModeMenuUp or Down button. 
Once you have pressed the button, the display will light up. 
 
 

 

Содержание 30751

Страница 1: ...Sunstrip Active MKII 110V V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 30751 MANUAL ENGLISH...

Страница 2: ...Sunstrips Active DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 13 1 DMX Mode 13 1 1 DMX address 13 1 2 DMX con...

Страница 3: ...Ds exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced...

Страница 4: ...t 5 minutes before handling Do not shake the device Avoid brute force when installing or operating the device Do not install lamps of higher wattage Only use the appropriate lamp for your unit Note th...

Страница 5: ...nce between light output and the illuminated surface must be bigger than 1 meter This distance may differ depending on the model The exact minimum distance will be mentioned in the corresponding manua...

Страница 6: ...ection with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED...

Страница 7: ...ne number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform thi...

Страница 8: ...sy setup Light source 10 x 110V 50W GU10 Ordercode SPHK498 Socket GU10 Lumen 300lm each Lamp Control modes Chase mode DMX mode Control protocol DMX 512 Dimmer 0 100 Beam Angle 35 Protection rate IP 20...

Страница 9: ...10 Neutrik Powercon IN Blue Max 20A 11 3 pin DMX signal connector IN Installation Remove all packing materials from the Sunstrip Active MKII 110V Check if all foam and plastic padding is removed Conn...

Страница 10: ...th a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 01 Loosen the 4 screws on t...

Страница 11: ...pply socket 04 When the Sunstrip Active is not connected with a DMX cable it functions as a stand alone device Please see page 13 for more information about the Chase mode Multiple Sunstrips Active DM...

Страница 12: ...rom a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic inte...

Страница 13: ...1 etc Please be sure that you do not have any overlapping channels in order to control each Sunstrip correctly If two or more Sunstrips are addressed similarly they will work similarly Controlling Aft...

Страница 14: ...s 1 DMX Mode With this mode you can set the DMX address and choose a DMX configuration 1 1 DMX address 01 Press and hold the Mode button for 5 seconds until the display starts blinking 02 Press the Mo...

Страница 15: ...lect the required built in program from 06 If you choose program the device will start with its built in chases 1 16 in sequence 07 If you choose all 10 LEDs will light up and remain On at 100 output...

Страница 16: ...hold the Down button for 2 seconds to select the previous character 05 Press the Up Down button to select a certain character Repeat step 3 5 to edit all characters 06 The text can hold a maximum of...

Страница 17: ...l 2 Dimmer intensity section 2 0 255 Gradual adjustment from dark to brightest 0 100 Channel 3 Dimmer intensity section 3 0 255 Gradual adjustment from dark to brightest 0 100 Channel 4 Dimmer intensi...

Страница 18: ...ll be significantly reduced Disconnect the mains power supply and then wipe the cover with a damp cloth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth Do not use alcohol...

Страница 19: ...is found Once the unit operates properly do not carry out following steps No Light If the light effect does not operate properly refer servicing to a technician Suspect three potential problem areas a...

Страница 20: ...t connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on...

Страница 21: ...pin DMX IN Signal output 3 pin DMX OUT Electro mechanical effects Light source 10 x 110V 50W GU10 Socket GU10 Lumen 300lm each Lamp Beam angle 35 Dimmer 0 100 DMX control via standard DMX controller...

Страница 22: ...21 Ordercode 30751 Sunstrip Active MKII 110V Dimensions Leftside Rightside...

Страница 23: ...22 Ordercode 30751 Sunstrip Active MKII 110V Notes...

Страница 24: ...2020 Showtec...

Отзывы: