background image

 

  

 

 

   

 

Ordercode: 30751 

Sunstrip Active MKII 110V 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 
 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never modify, bend, mechanically strain, put pressure on, pull or heat up the power cord. 

 

Never strain the cable insert or the female part in the device. There must always be sufficient cable 
going to the device. Otherwise, the cable will be damaged, which can cause serious damage. 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never lift the device holding it by the projector-head, as the mechanics may be damaged. Always 
hold the device by the transport handles. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never use the device without the lamp. 

 

Never ignite the lamp if the objective lens or any housing cover is open, as discharge lamps may 
expose and emit a high ultraviolet radiation, which may cause burns. 

 

In case of strobe fixtures: Never operate the stroboscope without protective shield! When the shield is 
cracked, replace it before using the device again. 

 

Never leave any cables lying around. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Never leave various parts of the packaging  (plastic bags, polystyrene  foam, nails,  etc.) within 
children’s reach, as they are potential sources of danger.

 

Do not insert objects into air vents. 

 

Do not open the device and do not modify the device.

 

Do not switch the device on and off in short intervals, as this will reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot). 
Allow the device to cool for at least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Do not install lamps of higher wattage. 

 

Only use the appropriate lamp for your unit. Note that product versions, that use other lamps, may 
be offered in the future. Check your product specification label for information. 

 

Only use the device indoors, avoid contact with water or other liquids (only applies to devices with 
IP<=65). 

 

Only operate the device after having checked if the housing is firmly closed and all screws are tightly 
fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always replace the lamp, when it is damaged or deformed due to the heat. 

 

Always keep the case closed while operating. 

 

Always allow a free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used, before cleaning or when 
replacing lamp! Only handle the power cord holding it by the plug. Never pull out the plug by 
tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

Make sure that the core diameter of extension cords and power cords is sufficient for the required 
power consumption of the device. 

 

If the lens is obviously damaged, it has to be replaced to prevent its functions from being impaired, 
due to cracks or deep scratches. 

 

If the external cable is damaged, it has to be replaced by a qualified technician.

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

Содержание 30751

Страница 1: ...Sunstrip Active MKII 110V V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 30751 MANUAL ENGLISH...

Страница 2: ...Sunstrips Active DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 13 1 DMX Mode 13 1 1 DMX address 13 1 2 DMX con...

Страница 3: ...Ds exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced...

Страница 4: ...t 5 minutes before handling Do not shake the device Avoid brute force when installing or operating the device Do not install lamps of higher wattage Only use the appropriate lamp for your unit Note th...

Страница 5: ...nce between light output and the illuminated surface must be bigger than 1 meter This distance may differ depending on the model The exact minimum distance will be mentioned in the corresponding manua...

Страница 6: ...ection with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED...

Страница 7: ...ne number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform thi...

Страница 8: ...sy setup Light source 10 x 110V 50W GU10 Ordercode SPHK498 Socket GU10 Lumen 300lm each Lamp Control modes Chase mode DMX mode Control protocol DMX 512 Dimmer 0 100 Beam Angle 35 Protection rate IP 20...

Страница 9: ...10 Neutrik Powercon IN Blue Max 20A 11 3 pin DMX signal connector IN Installation Remove all packing materials from the Sunstrip Active MKII 110V Check if all foam and plastic padding is removed Conn...

Страница 10: ...th a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 01 Loosen the 4 screws on t...

Страница 11: ...pply socket 04 When the Sunstrip Active is not connected with a DMX cable it functions as a stand alone device Please see page 13 for more information about the Chase mode Multiple Sunstrips Active DM...

Страница 12: ...rom a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic inte...

Страница 13: ...1 etc Please be sure that you do not have any overlapping channels in order to control each Sunstrip correctly If two or more Sunstrips are addressed similarly they will work similarly Controlling Aft...

Страница 14: ...s 1 DMX Mode With this mode you can set the DMX address and choose a DMX configuration 1 1 DMX address 01 Press and hold the Mode button for 5 seconds until the display starts blinking 02 Press the Mo...

Страница 15: ...lect the required built in program from 06 If you choose program the device will start with its built in chases 1 16 in sequence 07 If you choose all 10 LEDs will light up and remain On at 100 output...

Страница 16: ...hold the Down button for 2 seconds to select the previous character 05 Press the Up Down button to select a certain character Repeat step 3 5 to edit all characters 06 The text can hold a maximum of...

Страница 17: ...l 2 Dimmer intensity section 2 0 255 Gradual adjustment from dark to brightest 0 100 Channel 3 Dimmer intensity section 3 0 255 Gradual adjustment from dark to brightest 0 100 Channel 4 Dimmer intensi...

Страница 18: ...ll be significantly reduced Disconnect the mains power supply and then wipe the cover with a damp cloth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth Do not use alcohol...

Страница 19: ...is found Once the unit operates properly do not carry out following steps No Light If the light effect does not operate properly refer servicing to a technician Suspect three potential problem areas a...

Страница 20: ...t connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on...

Страница 21: ...pin DMX IN Signal output 3 pin DMX OUT Electro mechanical effects Light source 10 x 110V 50W GU10 Socket GU10 Lumen 300lm each Lamp Beam angle 35 Dimmer 0 100 DMX control via standard DMX controller...

Страница 22: ...21 Ordercode 30751 Sunstrip Active MKII 110V Dimensions Leftside Rightside...

Страница 23: ...22 Ordercode 30751 Sunstrip Active MKII 110V Notes...

Страница 24: ...2020 Showtec...

Отзывы: