Digital Controller

 

MAC6A/MAP6A

 

Instruction manual

 

 
 
 
 

 

 
 
 

 
 

Please ensure that this manual is given to the final user of this product.

 

 
 

 

 

 
 
 
 
 
 

MAP6F-1EE   March 2017 

Thank you for purchasing SHIMAX products. 
Please check that the delivered Item is the item you ordered. Read this instruction manual 
thoroughly and understand its contents before using this product. 

Содержание MAC6A

Страница 1: ...his manual is given to the final userof this product MAP6F 1EE March 2017 Thank you forpurchasing SHIMAX products Please check that the delivered Item is the item you ordered Read this instruction man...

Страница 2: ...psetting 33 6 5 FIX constant value control setting screens 38 6 5 1 Explanation of Ramp Soak function 39 6 6 Modesetting 46 6 6 1 Mode1 System setting 46 6 6 2 Mode2 PV setting screen 49 6 6 3 Mode3 O...

Страница 3: ...Exercise extreme caution asindicated CAUTION This mark indicates hazardous conditions that could cause damage to equipment and or facilities Exercise extreme caution asindicated NOTE This mark indicat...

Страница 4: ...ffersfrom input specificationshould notbe connectedto theinput terminal It may shorten the life of the product and or result in problems with the product Input DI AI CT and FB terminals are not insula...

Страница 5: ...ain body case against the following code table Check ofaccessories CAUTION Handling Instruction Do not operate the keys on the front panel with a hard or sharply pointed object Operate the keys only b...

Страница 6: ...oad 2 S Voltage pulse 12V DC max20mA I Current 4 20mA DC max500 V Voltage 0 10V DC max2mA Event Output E Event output 1point EV4 240V AC 2A Resistance load DI External operation input D 7 Points DI1 7...

Страница 7: ...or where inductive interference can affect the operation of the instrument Where undergo influence of the equipment which generates a high frequency Where the instrument is exposed to dew drops or dir...

Страница 8: ...nal dimension Unit mm Panel cutout Unit mm Note Proximity attachment by a single hole is possible only in the case of horizontal direction When an apparatus that was attached in vertical direction is...

Страница 9: ...0 6Nm For wiring for power supply use a 600V vinyl insulated wire or cable which is 1mm2 or larger in section or a wire or cable of equivalent for higher performance For Thermocouple input use compen...

Страница 10: ...9 4 5 Terminal arrangement Note If input type is thermocouple or voltage errors may occur when terminal 11 and terminal 12 terminal are short circuited...

Страница 11: ...ut 21 COM 22 CCW 23 AOOutput 24 25 COM DO Output DO1 3 DO4 6 26 DO1 27 DO2 28 DO3 29 DO4 30 DO5 31 DO6 29 CW Feedback potentiometerinput 30 COM 31 CCW 29 COM CT Input 30 CT1 31 CT2 32 AI input 33 34 S...

Страница 12: ...11 5 Names and Functions of Parts on Front Panel MAP6A MAC6A...

Страница 13: ...f program control s standby or flat part control Off at the time of FIX control selection OUT1 At the time of a contact or a voltage pulse output On with ON and Off with OFF At the time Current Output...

Страница 14: ...en it jumps to the screen of operation Mode 1 Shift key Move the digit which set the value The digit can be changed are blinked Down key continuously the value as well consecutively decreases A decima...

Страница 15: ...shifts to setting screen Pattern key MAP6 only At a reset RST increment pattern No on the basic screen Press at the lead screen on the step setting screen it sift to lead screen on the Program pattern...

Страница 16: ...ed at mode 2 Basic screen 3sec MODE MODE MODE 3 MODE 14 Each setting screen Every time you press the key on a basic screen it shifts to each screen of the basic screens Press the key for 3 seconds on...

Страница 17: ...16 Press the key on the first setting screen of each screens then it shifts to the next screen Every time you press the key it shifts to the next setting screen...

Страница 18: ...on In the case of two output type the switchover between automatic and manual is operatable through output 1 and output 2 The setting is altered simultaneously Output Monitor Output Monitor Output Mon...

Страница 19: ...and key lock level 2 4 is set change of setting impossible Execution Program No can be changed by pressing at the RST in Program When no key operation 3 minutes or more screen will be shifted to basic...

Страница 20: ...t the time of automatic output monitor display only Refer to automatic manual switch over and setting method at the time of manual operation A manualoutputis canceledwhenanoperationmodeismadeinto When...

Страница 21: ...e Lower Display Pattern No Step No On going step and the remaining repeating time of pattern are displayed A remaining time and actually performed times are switchable by pressing the key for 3 second...

Страница 22: ...topping while HOLD is in execution HOLD is canceled if is chosen while HOLD is in execution The remaining time of the step is performed based on a program skip is unable to perform while HOLD is in ex...

Страница 23: ...l Value Setting Range AT is performed by ON selection and canceled by OFF selection Not displayed at the time of STBY RST a manual output and P proportional band OFF Except in the setting of keylock O...

Страница 24: ...lute valuealarm Belong to Range settingand scaling Lower limit absolute valuealarm Belong to Range settingand scaling Upper limit deviation valuealarm unit Lower limit deviation valuealarm unit Within...

Страница 25: ...operating point setting screen Initial value Maximum value ofsetting range Setting range within measuringrange Display when EV1 allotted to or EV2 EV4 operating point setting screen The operating poin...

Страница 26: ...ll be activated before the time set to the End When 10 0 sec set EV will be activated 10 0 sec before 10 0sec to the End when 10 0 sec set EV will be activated 10 0 sec from the End In case of 0 sec s...

Страница 27: ...are maintained evenif thestateof OFF WhenEV and DO arein a latchingstate decimal point of the minimum digit blinks and it shows that release are possible If key is pressed EV and DO released and a dec...

Страница 28: ...is chosen on Action mode2 screen of basic screens If key is pressed for 3 seconds on lead screen 1to 8 or ALL it returns to basic screen Basic screen Program pattern 1 leadscreen key3seconds key 3sec...

Страница 29: ...setting screen Press each step screen it shift to lead screen of program pattern setting screen Press key 3seconds at any program step lead screen It shift to Basicscreen 6 4 1 Program pattern common...

Страница 30: ...minute second Setting range hour minute hour Number of pattern settingscreen Initial Value Setting range MAX 96steps MAX 48steps each pattern MAX 32steps each pattern MAX 24steps each pattern MAX 16st...

Страница 31: ...g lowerlimit Setting range sensor input type within measuring range linear input type within scalingrange Moreover within limit of SV limiter When SV is chosen on start mode setting screen this screen...

Страница 32: ...Time unit belong to the Time unit setting screen During program operation the SV value on program step proceed to flat step from ramp step the PV value some time delay from the SV value and the flat s...

Страница 33: ...60 minutes When starts at PV 100 30 70 therefore 60 minutes x70 42 minutes 18 minutes shortening However depending on the spatial relationship between PV Start SV and attainment SV it may become SV s...

Страница 34: ...ep setting screen Press at each step setting screen it move to same setting screen on other pattern No Step1 setting lead screen Step2 setting lead screen Step96 setting leadscreen 1sec 1sec Step1 Exe...

Страница 35: ...me signal ON time is the time that will be ON after step bigan Time signal setting screen is displayed at EV or DO I is allotted to time signal Time signal setting has to be OFF when time setting is l...

Страница 36: ...itial value Setting range 00 00 300 00 min sec hour min 0 0 3000 0 hour OFF time is the time that will be off after step bigan Time signal 2 ON time setting screen Same as Time signal1 Time signal 2 o...

Страница 37: ...signal 3 ON time setting screen Same as Time signal1 Time signal 3 off time setting screen Same as Time signal1 Time signal 4 ON time setting screen Time signal 4 OFF time setting screen Same as Time...

Страница 38: ...uealarm Lower limit absolute valuealarm Upper limit deviation valuealarm Lower limit deviation valuealarm Within deviationalarm Without deviation alarm Independent EV setting screen in the numerical v...

Страница 39: ...d for 3 seconds on lead screen of SV1 SV8 it returns to basic screen Basic screen SV 1 leadscreen 3seconds Press and at SV 1 lead screen it move to SV2 SV3 SV4 Ramp Soak function mode setting screen I...

Страница 40: ...oak time separately 4 Automatic distinction in the slope direction Up Down 5 It s possible to allot Ramp Status Ramp ON OFF_Delay signal to Event DO 6 It s possible to allot Soak Status Ramp ON OFF_De...

Страница 41: ...anged will be end SV value Triger B Example of TriggerB Execution SV No 1 Execution SV No 2 time Value Value Trigger C SV value changed for manual key operation Invalid It will calculate SV value just...

Страница 42: ...on Special case matter AT will be waiting when AT starting during Ramp is execute and AT will be start after Ramp will be finish AT waiting Executing AT Ramp time Execution SV AT ON Start SV It cannot...

Страница 43: ...ill be changed Execution SV 300 Execution SV 500 SV Change Start SV 0 Ramp time Ramp time WhenRamp timewillbe changedduringRamp functionis proceeding timehavenotto beinitialized Itwillbe calculated by...

Страница 44: ...at the Ramp mode2 Status operationexample Ramp time Status time Status time Execution SV Start O _D O _D O _D O _D Power failurecompensation When set the Power failure compensation is activate Ramp f...

Страница 45: ...sed by power off or EV latching off Soak signal will be turned off when timer cleared Latching off status Event DO cannot be activate when SV No changed before Status time is not up Operation example...

Страница 46: ...s Execution SV being reflected in basic screen Being initialized when measuring range unit and scaling are changed SV1 PID No settingscreen SV1 leadscreen Initial Value Setting range 1 2 3 4 5 6 7 and...

Страница 47: ...ode1 System setting Mode 1setting lead screen Press key for 3 seconds on basic screen thendisplayed Press the key then it shifts to the first setting screen keylock setting screen Press key to each mo...

Страница 48: ...e upperlimit Setting range SV limiter lower limit value 1 measuring range upper limit value Bar graph settingscreen Initial value Setting range deviation value OUT1 output rate OUT2 output rate Step t...

Страница 49: ...the functions are executing Power failure compensation settingscreen Initial value Setting range Power failure compensation is the function that can be remained the status of operation before powerfa...

Страница 50: ...reen PV offset correction PV bias setting screen Initial Value 0 0 Setting range digit Used for correction of input errors such as sensor If offset correction is performed control is also performed wi...

Страница 51: ...code Being initialized when measuring range is changed Temperature unit settingscreen Initial value Setting range The temperature unit at the time of a sensor input is set up from Kelvin Not displaye...

Страница 52: ...ily changed into that of 10 or 50 000 count Upper limit value cannot be set as lower limit value of 10 count or less or that of over 50 000 count Input scaling Decimal point position setting screen In...

Страница 53: ...ange Setting range 10 110 of measuring range within 19999 32000 Upper scale point is set Mode 2 leadscreen 6 6 3 Mode3 Out1setting MAP6 has 8kinds of PID setting PID1 PID8 both Out1 and Out2 It can be...

Страница 54: ...120seconds Setting range 0FF 1 6000seconds When performing auto tuning no necessity for a setting basically This screen is not displayed at the time of ON OFF operation Becomes P operation or PD opera...

Страница 55: ...al value 5digit Setting range 1 9999digit The differential gap at the time of ON OFF operation lower point is set Displayed at the time of P OFF ON OFF operation setup Out1 PID Upper differential gap...

Страница 56: ...PID method is set 2 Initialized at Program and Fix has changed Refer to Explanation of Flex PID method Display at the time of PID method 2 Out1 Flex PID factor C setting screen Initial Value 0 40 Outp...

Страница 57: ...tput limit setting value During AT tuning function output value will be 0 and 100 with nothing relate output limit setting value At P OFF operation Output type C and S will be 0 and 100 with nothing r...

Страница 58: ...sec This is the function that eases change of output at the time of a power on and startup from 0 to 100 Does not function at the time of OFF setup Output 1 proportional periodic time setting screen I...

Страница 59: ...ut 1 characteristics settingscreen Initial value RA Setting range RA DA Characteristics of control output is chosen from RA heating characteristics and DA coolingcharacteristics Out1 PID common settin...

Страница 60: ...when option is not added Mode 4 has PID dead band setting screen instead of Out1 PID manual reset setting screen Out2 PID1 leadscreen Same asOut1 Dead band settingscreen Initial value Setting range di...

Страница 61: ...ditions P operation manual reset 50 0 1 OUT 1 RA heating OUT 2 DA cooling operation control output 1 RA characteristics control output 2 DA characteristics output 100 output 0 DB DB 0 DB Setting Value...

Страница 62: ...teristic Output 1 2 Adjustment of follow for Start up and SV change The turbulence response and the SV change follow can be individually set by Flexible PID method in MAC6 It already set up the turbul...

Страница 63: ...Value or SV value Being initialized when measuring range and scaling changed Zone 1 SP set point settingscreen Initial value 0 0 Setting range within measuring range scaling range and limit setting C...

Страница 64: ...g initialized when measuring range and scaling changed Zone 4 SP set point settingscreen Initial value 0 0 Setting range within measuring range scaling range and limit setting Change PID No at set poi...

Страница 65: ...value Zone value Zone value No Change point 2 Zone hysteresis is set as the lower side of the SP Value When same value is set in plural SP value priority is given to younger SP Number Zone hysteresis...

Страница 66: ...ault Upper limit absolute valuealarm Lower limit absolute valuealarm Within Absolute Valuealarm Without Absolute Valuealarm Scale overalarm Upper limit deviation valuealarm Lower limit deviation value...

Страница 67: ...performed When RUN STBY RST is switched When AUTO MAN is switched Not displayed when the event 1 mode are as follows Being initialized if measuring range scaling and unit are changed Event 1latching s...

Страница 68: ...l gap of DO 1 is set Not displayed when the event 1 mode are as follows Being initialized if measuring range scaling and unit are changed Stand by operation settingscreen Initial value Setting range N...

Страница 69: ...nitialized if measuring range scaling and unit are changed DO character settingscreen Initial value Setting range normal open normalclose Not displayed when DO 1 modeis Note If is chosen relay turns t...

Страница 70: ...s of continuation is occupied by the younger DI allotment Level Level Level Edge Auto tuningexecution selection 1 Level Priority is given to younger number selection Level 3 bits of continuation is oc...

Страница 71: ...n when a keylock is not OFF conducting of DI is effective The same operation other than is impossible to allot to DI1 DI7 at a time Operation allotted to DI takes priority over DI Key operation cannot...

Страница 72: ...l Value Refer to the table below Setting range Refer to thetable below Not displayed when AO mode is Non Function Character Non Execution PV SV Deviation Output Output CT1 CT2 Servo position MODE Sett...

Страница 73: ...e of analog output value 4 20mA or 0 10V is set up by For example output value of a lower limit value in each setup are 8mA 25 0 12mA 50 0 16 75 0 and 20 100 0 respectively Not displayed when AO mode...

Страница 74: ...mit value in each setup are 8mA 25 0 12mA 50 0 16 75 0 and 20 100 0 respectively Not displayed when AO mode is Non If set as the same value as _ and _ it is fixed to the value An analog output limiter...

Страница 75: ...ntrol it can be set at program control but not effective Manual operation point can be effected at Manual control Function Character Non Executing SV offset correction Out1 lower limit Out1 upper limi...

Страница 76: ...raight line which connects zero point and correction maximumvalue AI filter settingscreen Initial value 0 Setting range 0 10000 sec When input change is violent or noise is overlapped used in order to...

Страница 77: ...DOsetting AI scaling upper limit setting screen Initial value 0 or upper limit of each range Setting range refer to the setting range table Upper limit value of range allotted to analog input is set u...

Страница 78: ...case of a current or voltage pulse output is not displayed is not displayed without current output or output 2 option CT1 delay time settingscreen Initial value 0 5 Setting range 0 1 1000 0 sec When...

Страница 79: ...erating point setting screen alarm output is issued as breaking alarm When the targeted output is OFF if detected current is higher than the allotted event s operating point short circuit earth fault...

Страница 80: ...ensation S SV Compensation is not display at RTD and TC input display when AI function is allotted to SV Set point 1 position setting screen Initial Value Setting range 5 00 105 00 within measuring ra...

Страница 81: ...excessive current to loads such as a heater Soft start functions in the following conditions At the time of the power on in automatic operation STBY RST RUN and normal return from scale over Setup of...

Страница 82: ...one pattern is completed When AT is not completed within 1 pattern AT conducting is released when one pattern is completed Even in inclination step AT is performed if it is in HOLD state AT at the tim...

Страница 83: ...sistance bulb 3 check of input voltage value and current value input transmitter and specification matching of incoming signal and meter specification L Scale over in lowerlimit 1 when input exceeds l...

Страница 84: ...RG green LED Program DO1 6 yellow LED GUA green LED Program HLD green LED Program Up yellow LED Program Flat yellow LED Program Down yellow LED Program 2 Display accuracy 3 Accuracy maintenance range...

Страница 85: ...erences of lead wire Burn out Compensation accuracy of reference junction Reference junction mode Resistance bulb Stipulated current Resistance latitude of lead wire Inferences of lead wireresistance...

Страница 86: ...86 Measuring range Thermocouple Character Centigrade Fahrenheit Kelvin RTD Linerinput Scaling Span or less Decimalpoint Non...

Страница 87: ...10000 Units OFF 1 6000s P or OD operation by OFF setting OFF 1 3600s P or PI operation by OFFsetting 50 0 Effective at I OFF 20000 30000 Units L 0 0 99 9 H 0 1 100 0 resolution 0 1 OFF 0 1 300 0s res...

Страница 88: ...phases Control loop alarm Heaterbraking 3 phases Control loop alarm loop Step signal Pattern endsignal Program end Step holdsignal Program signal Up slopesignal Down slopesignal Guarantee signal Time...

Страница 89: ...G FIX MAN Level MANUAL AUTO AT Edge Auto tuningexecution PTN selection PTN1 PTN8 Level Priority is given to younger number PTN 3bit selection Level 3 bits of continuation is occupied by the younger DI...

Страница 90: ...method 4 Communications distance 5 Communication speed 6 Data format 7 Master mode 8 Slave address 9 Parameter preservation mode 10 Error detection 11 Flow control 12 Delay 13 Communication code 14 P...

Страница 91: ...Max load 300 load regulation 0 05 FS 0 10V DC Max load 2mA 0 1 FS 0 2 FS at PVoutput Within measuring range or output range 0 0 100 0 reserve setting permitted About 1 50000 50 166 7 250 500 msec Cur...

Страница 92: ...densation Height Altitude of 2000m or less Category Contamination degree 2 20 65 100 240V 90 264V AC 50 60Hz Normal 50dB orhigher Power source Normal 100ns 1 s 1500V Between input output terminal and...

Страница 93: ...e CT Control Out2 Voltage pulse Current Voltage FB AO DO1 6 EV1 3 Infrared raycommunication EV4 Communication RS232C 485 No insulation Functional insulation Basic insulation URL http www shimax co jp...

Отзывы: