If the weight is locked, press
『
Hold
』
again to unlock and it goes back to
normal weighing mode and “Hold” indicator goes off.
In weight locked status, it refuses to tare, clear tare and zero.
● Percentage display F2.1 = 2
Display introduction
Displaying
【
】
indicates 20.5 %.
Pr = present actual weight / measuring range ×100%
Pressing
『
Hold
』
key to change over between percentage and weight
● Weight check, sorting scale function F2.1 = 3
Function description:
Parameters as F2.2 = A, F2.3 = B, F2.4 = C, F2.5 = D etc shall be set.
Presently displayed weight is X.
If X ≤ A, no weight check or sorting will be performed.
If X
<
(B – D), it stands for short weight; the short-weight icon goes
on.
If (B – D) ≤ X ≤ (B – C), it stands for PASS; PASS icon goes on.
If X
>
(B – C). It stands for overweight; overweight icon goes on.
Target value acquisition
Hold
『
Total
』
until
【
TARGET
】
is displayed, and then press
『
ON/OFF
』
;
the present target value goes on and flashes.
If F2.6 = 0, press
『
ON/OFF, the present weight on the scale will be taken as
new target value and it exits setting interface.
If F2.6 = 1, it displays
【
】
, requiring modifying the target value
manually. After the modification, press
『
ON/OFF
』
to save the data and exit
the setting interface.
Press
『
Hold
』
to exit target value acquisition.
●
Accumulating scale function F2.1 = 4
How to operate
In normal weighing state, the scale is at zero; apply the scale with
load and press
『
Total
』
on the operation panel; if it displays
【
】
, it means that the present weight has been counted in