Serial-port Setting
F4.1 UART0 Communication Interface Parameter
F4.1.1 Communication Mode
Selectable Parameters
:
0
---- command out
1
---- continuous output
2
---- Key output
F4.1.2 Setting of Data and Check Pit
Selectable Parameters:
:
8_N_1 ---- 8-pit no parity check (default value)
7_E_1 ---- 7-pit odd parity check
7_O_1 ---- 7-pit even parity check
8_E_1 ---- 8-pit odd parity check
8_O_1 ---- 8-pit even parity check
F4.1.3 Baud Rate
Selectable Parameters:600, 1200, 2400
,
4800
、
9600
(
default value)
F4.2 Parameter Setting of UART1 Printing Interface
F4.2.1 Whether to connect the printer
Selectable Parameters: 0 ---- not connected to the miniprinter (default)
1 ---- connected to the miniprinter
F4.2.2 Printing Carriage Return Character
Selectable Parameters: 0~9 carriage return characters
(default value: 3)
F4.2.3 Printing Setting of Accumulative Scale
Selectable Parameters: 0 ---- total accumulative data for printing (default value)
1
---- printing total accumulative
data
F4.2.4 Print language setting
Selectable Parameters: 0 ---- in Chinese (default)
1 ---- in English
(
Eng,CH1
)