Checking
i. The master machine sends data of the following format con-
sisting of 2-byte sequence No. and 254-byte AAH data to the
satellite machine. The master machine displays the sequence
Nos.
Test data format (1 packet: 256 bytes)
XXXX : Sequence No. 2 bytes (4-digit binary coded decimal
number)
AA :
Transfer (AAH) ~ 254 bytes
ii. The satellite machine returns the data it has received, to the
master machine as it is. The satellite machine displays the
sequence No. on the screen.
iii. The master machine receives the data and then checks the
sequence Nos. and 254-byte AAH data. If an error occurs, the
master machine displays an error code and ends the test. If
there are multiple satellite machines, steps i and ii are re-
peated.
The master machine advances the sequence No. when data is
transferred successfully between it and the satellite machines.
Steps i - iii are repeated.
Error display
The following error codes are used (same as for TCP/IP HANDLER)
01
Command error (excluding the time when data is sent)
02
No data received
03
Received data size present
Received data left
04
Receiving station not ready for receiving (when sending)
"NRDY" is returned because the receiving station is not
ready for receiving.
05
Receiving buffer full(when sending)
The receiving side’s controller receive buffer is full.
06
Resend error(When sending)
The number of retries exceeds the setting (5 times) when
no response is obtained.
07
Collision error (When sending)
If a collision occurs
08
Line busy time out
Data cannot be sent due to multiple stations communicating
09
Receiving data size over (when receiving)
Insufficient size of receiving buffer.
0A
Hardware error
Interface error (No SRN interface or defective SRN
controller)
How to exit the program
Press the CANCEL key to exit the program.
7) MCR & DRAWER Diagnostics
The program checks the MCR and drawer.
The following menu appears on screen.
The cursor shown in reverse video can be moved using the up/down
arrow keys. Move the cursor to the menu item you want to execute
and select by pressing the ENTER key to execute the corresponding
program. Press the CANCEL key to return the screen to this sub-
menu.
7)-1. Magnetic Card Reader Check
The program performs the read test of an optional UP-E13MR.
The test program reads a magnet card using the ISO7811/1-5 stand-
ard and prints data on the journal.
Press the CANCEL key to return the screen to the submenu.
Checking
The program reads tracks 1 - 3 of a magnet card using the
ISO7811/1‘5 standard and prints the data using ASCII codes.
JOURNAL print
Data read by the MCR is printed in the areas XXXXX. If an error
occurs, the following error codes are displayed. Until the program
is terminated, the error code is repeated, standing by for reading.
Display
How to exit the program.
Press the CANCEL key to exit the program.
XX
XX
AA
AA
AA
AA
AA
AA
1
2
3
4
5
254 255 256 byte
DRAWER 2 Check
DRAWER 1 Check
MCR Check
MCR&DRAWER Check
XXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXX
TRACK2:
TRACK1:
MCR Check
XXXXXXXXXXXXXXXXXXXXXXXXXXX
TRACK3:
TRACK3 : PASS
TRACK2 : MCR ERROR
TRACK1 : BUFFER EMPTY
MCR Check
Receive data is
empty
Data error after
detecting card.
Data has been read
successfully.
Содержание UP-600
Страница 8: ......
Страница 77: ...CHAPTER 9 PWB LAYOUT 1 MAIN PWB 1 A side R VRD RC2EY103J is added IC1 94pin R71 ...
Страница 78: ...2 B side Symbol PartsCod ...
Страница 79: ...2 CKDC PWB 3 DISPLY MCR PWB 1 A side 2 B side 4 RS232 RELAY PWB 1 A side 2 B side ...
Страница 80: ...5 IPL ROM PWB 1 A side 8 POP UP DISPLY 9 LCD I F PWB 2 B side 6 TCP IP RELAY PWB 7 VR PWB ...
Страница 81: ...10 TCP IP I F PWB B side A side ...