ER-A5RS CON3 (RSCN1)
S1-1
S1-2
S1-3
CHANNEL
0
0
0
Disabled
0
0
1
No setting allowed (Standard RS)
0
1
0
CHANNEL 2
0
1
1
CHANNEL 3
1
0
0
CHANNEL 4
1
0
1
CHANNEL 5
1
1
0
CHANNEL 6
1
1
1
CHANNEL 7
ER-A5RS CON4 (RSCN2)
S1-4
S1-5
S1-6
CHANNEL
0
0
0
Disabled
0
0
1
No setting is allowed (Standard RS)
0
1
0
CHANNEL 2
0
1
1
CHANNEL 3
1
0
0
CHANNEL 4
1
0
1
CHANNEL 5
1
1
0
CHANNEL 6
1
1
1
CHANNEL 7
How to exit the program
Press the CANCEL key to exit the program.
4)-2. CH1 Check
Checking
If any channel is not set, the error message (ERROR: CHx) ap-
pears. When the channel is set, the following checks are per-
formed.
i. Control signal check
ERn
RSn
DRn
Cin
CDn
CSn
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
The program performs the read checks of the above inputs and
interrupt checks of CS, CI, and CD.
During the read check, ER and RS are changed over in the above
order, checking the logic of DR, CI, CD and CS.
If the check result does not agree with the logic in the table, the
error message appears. "ON" in the table means active low and
"OFF" means active high.
In the interrupt check, the CS, CI and CD interrupts are permitted
one by one (The mask is canceled.).
The error message appears if an interrupt does not occur when
each signal is active or if an interrupt occurs when each signal is
not active.
Four cycles of the above check is performed.
ii. Data transfer check
As check data, loop back data transfer of 256 bytes of 00H - 0FFH
is performed. The baud rate is 38400 bps.
iii. TIMER CHECK (RS232 ON BOARD TIMER)
Before starting the check ii, perform the RCVDT start of the timer
you want to check and set to 5 ms. Make sure::
•
No TRQ- is generated during the implementation of check ii.
•
TRQ- is generated at 5 ms after check ii is completed.
Display
Details of the errors are printed on the journal.
ERROR
No.
ERROR print
Details of ERROR
1
ER-DR : ERROR
ER-DR LOOP ERROR
2
ER-CI : ERROR
ER-CI LOOP ERROR
3
RS-CD : ERROR
RS-CD LOOP ERROR
4
RS-CS : ERROR
RS-CS LOOP ERROR
5
CI INT : ERROR
No CI interrupt occurs.
6
CD INT : ERROR
No CD interrupt occurs.
7
CS INT : ERROR
No CD interrupt occurs.
8
TXEMP : ERROR
TXEMP is not set.
9
TXEMP INT : ERROR
TXEMP interrupt does not
occur.
10
TXRDY : ERROR
TXRDY is not set.
11
TXRDY INT : ERROR
TXRDY interrupt does not
occur.
12
RCVRDY : ERROR
RCVRDY is not set.
(Not possible to receive.
TRQ- occurs during the
implementation of check ii.)
13
RCVRDY INT : ERROR RCVRDY interrupt does not
occur.
14
SD-RD : ERROR
SD-RD LOOP ERROR
(DATA ERROR)
15
SD-RD : ERROR
SD-RD LOOP ERROR
(DATA ERROR)
16
TIMER : ERROR
TIMER ERROR
(After check ii is completed)
17
TIMER INT : ERROR
TRQ1- interrupt does not
occur.
How to exit the program
Press the CANCEL key to exit the program.
PASS!!(or ERROR!!)
RS232 CH1 Check
Содержание UP-600
Страница 8: ......
Страница 77: ...CHAPTER 9 PWB LAYOUT 1 MAIN PWB 1 A side R VRD RC2EY103J is added IC1 94pin R71 ...
Страница 78: ...2 B side Symbol PartsCod ...
Страница 79: ...2 CKDC PWB 3 DISPLY MCR PWB 1 A side 2 B side 4 RS232 RELAY PWB 1 A side 2 B side ...
Страница 80: ...5 IPL ROM PWB 1 A side 8 POP UP DISPLY 9 LCD I F PWB 2 B side 6 TCP IP RELAY PWB 7 VR PWB ...
Страница 81: ...10 TCP IP I F PWB B side A side ...