NAMES AND FUNCTIONS OF FACEPLATE
SPECIFICATIONS
SETTING PROCEDURE
P r o d u c t i s s u b j e c t t o c h a n g e w i t h o u t n o t i c e .
RESET
H5KLR
K/P
RESET
CP1
CP2
RUN
OUT1
OUT2
Set1
Set2
POWER ON
or
RESET
Reset
INPUT MODE
OUTPUT MODE
OUTPUT 2 TIME
OUTPUT 1 TIME
MINIMUM RESET TIME
DECIMAL POINT
PRESCALE VALUE
KEY PROTECTION LEVEL
POWER OFF MODE
COUNT SPEED
Change
the mode
RESET
Save and back to the
operation mode
Switch to output 2 time
setting mode
Change
the set value
Switch to output
setting mode
Change
the mode
Switch to count speed
setting mode
Change
the set value
Switch to output 1 time
setting mode
Change
the set value
ϡʳ
Not available for Mode N and Mode F
Switch to reset time
setting mode
Change
the set value
Switch to prescale value
setting mode
Change
the set value
Switch to key protection level
setting mode
Switch to the position of
decimal point setting mode
Move the decimal
point position
Change
the set level
Switch to power off
setting mode
Change
the mode
Switch to Input
setting mode
ϡ
UP/DOWN MODE not available on ASK-4DR
ϭ
, H5KLR-8/-11 type
Changing the digit
of prescale value
H5KLR
MULTI-FUNCTION DIGITAL COUNTER
User's Manual
SAFETY PRECAUTION
This manual uses the following symbols to ensure safe operation of this timer.
WARNING
CAUTION
Warnings are indicated when mishandling this product might result in death or serious injury
Cautions are indicated when mishandling this product might result in minor injury to the user,
to user.
or only physical damage to the timer.
Θ
Note this incorrect wiring of this product can damage it and lead to other hazards. Make sure the product has
been correctly wired before turning the power ON.
Θ
Before wiring, or removing / mounting the product, be sure to turn the power OFF. Failure to do so might cause
electric shock.
Θ
Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.
Θ
Do not disassemble the product. Doing so might cause electric shock or faulty operation.
Θ
Use the product within the operating ranges recommended in the specification (temperature, humidity, voltage,
shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.
Θ
Firmly tighten the wires to the socket. Insufficient tightening of the wires to the socket might cause fire.
WARNING
CAUTION
When using this product in applications
that require particular safety or when
using this product in important facilities,
please pay attention to the safety of the
overall system and equipment. Install fail-
safe mechanisms, perform redundancy
checks and periodic inspections and
adopt other appropriate safety measures
when it is necessary.
RESTRICTIONS ON USE
Operating voltage
Allowable operating
voltage range
Rated frequency
Contact rating
Count speed
Power consumption
Life
Ambient temperature
Ambient humidity
Weight
Mechanical : 5,000,000 times / Electrical : 100,000 times
85 ~ 110% of rated operating voltage
50 / 60Hz
MAX 30 cps or 1,000 cps
250VAC 5A (Resistive load)
Approx. 2.5VA
-10
Д
+50
°
C
MAX 85% RH
Approx. 120g
AC/DC : 12
Д
48V / AC/DC : 100
Д
240V
RESET
Upper display
Display PV values (current count values,
etc.) or setup items.
Performing arithmetic shift operations and
switches the display. Hold down for at least
3 seconds to enter setting modes.
Lower display
Display SV values (set count values, etc.)
and other parameter values.
key :
Used for incrementing or decrementing
numeric values. And show the first set value
or second set value.
LEDs
RUN: Counting indicator
OUT1: Control output 1 indicator
OUT2: Control output 2 indicator
RESET: Reset indicator
CP1: Signal input 1 indicator
CP2: Signal input 2 indicator
Set1: 1st set value indicator
Set2: 2nd set value indicator
K/P: Key protection indicator
key :
Reset the output or save the value
of setting.(after save than back to
the operation mode)
key :
RESET
Mode N
Mode F
Mode C
9999
999.9
0.01~9.99
99.99
Lock function key
Lock reset key
Power off reset
Power off memory
Lock preset value key
Lock all key
Mode R
Mode K
Mode P
Mode Q
Mode A
0.01s
0.05s
0.1s
0.2s
0.5s
1s
2s
10s
20s
5s
0.01s
ϡ
Available on H5KLR-11 type only
Hold
0.05s
0.1s
30 cps
1k cps
20ms
1ms
0.2s
0.5s
1s
2s
10s
20s
5s
UP
DOWN
UP/DOWN A
UP/DOWN B
UP/DOWN C
SPECIAL FUNCTION KEY
ON / OFF Key
protect
PRESS FOR 3s
PRESS FOR 3s
Switch to input setting mode
RESET
Switch to input setting mode
(1)Stop
(2)Counting
PRESS
FOR 3s
PRESS
FOR 3s
or
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
Switch to input setting mode
RESET