SJGF60XT
18
[7] TROUBLESHOOTING
SELF-DIAGNOSIS MODE
1.
Outline
1-1.
The self-diagnosis mode stores fault data for 5 days in the past (including “today”), and displays them by the date
•
in the order of occurrence.
Self-diagnosis data to be displayed
Storage of self-diagnosis result
Current fault
Fault history
All faults that have currently occurred
(Displayed in the order of fault number)
Faults that occurred in the past
fi
ve days
(Displayed by the date in the order of occurrence)
Storage of fault data for the past
fi
ve days
(Up to 9 items per day)
Self-diagnosis display
•
Mode input
“Current”
fault display
“Today” fault
history display
“1-day before”
fault history display
“2-days before”
fault history display
“3-days before”
fault history display
“4-days before”
fault history display
Button
operation
Button
operation
Button
operation
Button
operation
Button
operation
Display priority is given to the upper stages
of self-diagnosis display (Table 1) (All items)
The last fault on that day is displayed first, and the older ones
are displayed in the order of occurrence. (Up to 9 items per day)
(Note 1) Self-diagnosis result data for 5 days (including “today”) are stored. 24 hours from the time when the
refrigerator power supply turned ON is de
fi
ned as “one day”.
24 hours
24 hours
24 hours
24 hours
24 hours
24 hours
Today
Current time
1-day before
2-days before
Stored data
3-days before 4-days before
n-days before
Refrigerator power supply
is turned ON
(Note 2) How to clear stored data
After turning ON the power to the main unit, open the doors of the refrigerator compartment and the ice
1)
compartment within 2 minutes, and press and hold the [
戻る
] button for 5 seconds or longer.
With the doors of the refrigerator compartment and the ice compartment opened, press and hold the [
2)
戻る
]
button for 5 seconds or longer again.
Self-diagnosis mode
1-2.
Mode input method
1)
With the refrigerator compartment door opened (the temperature control
1)
lamp unlit), press and hold the [
メニュー決定
] button for 5 seconds.
(The buzzer sounds, “beep, beep”.)
The refrigerator enters the self-diagnosis mode.
* The self-diagnosis mode will be automatically canceled when the status
with no button operation continues for 3 minutes.
* If the refrigerator does not enter the self-diagnosis mode, a fault with the
door switch system can be considered.
クリーン
[
メニュー決定
] button