SJGF60XT
17
Specifi cations of Refrigerant Valve Operation
3-4.
Modes and operating conditions of refrigerant valve (3-way valve)
1)
Valve is fully closed:
1.
• This mode is used in compressor OFF status.
Only fine capillary is opened:
2.
• During normal cooling operation
Only wide capillary is opened:
3.
• During cooling operation under large load
Both capillaries are opened
4.
• The refrigerator is set in this mode for only one minute after the power supply is turned ON. This mode is used for
vacuuming. During cooling operation, this mode is not used.
• Differentiation between
fi
ne capillary and wide capillary
- Fine capillary: Capillary tube A
- Wide capillary: Capillary tube B
- The
fi
ne capillary is identi
fi
ed with a yellow mark.
Fault and status of refrigerant valve
2)
• There is no method to give an instruction from the PWB and con
fi
rm the valve position.
Refrigerant valve status
Problem
1
Both capillaries are opened, and the valve does not operate.
No problem on cooling operation
No problem
2
Only the
fi
ne capillary is opened, and the valve does not operate.
Cooling performance deteriorates under large load.
Refrigerant shortage may occur, causing frost around
the evaporator inlet to increase.
3
Only the wide capillary is opened, and the valve does not operate.
No problem on cooling operation
No problem
4
Both capillaries are closed, and the valve does not operate.
Cooling operation is disabled.
Cooling operation is disabled even when the
compressor is ON.
• Fault of the refrigerant valve cannot be displayed in the self-diagnosis mode.