LH75400/01/10/11 (Preliminary) User’s Guide
UART2
6/17/03
20-39
20.3.2.28 BRGA Configuration Register
Register Bank: 3
BACF is the BRGA Configuration Register. The BACF Register defines the BRGA clock
sources and operating mode.
Table 20-65. BACF Register
BIT
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
FIELD
///
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RW
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
BIT
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
FIELD
///
BAM
///
RESET
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
RW
R
R
R
R
R
R
R
R
R
R
R
R
R
RW
R
R
ADDR
0xFF 0x04
Table 20-66. BACF Register Definitions
BITS NAME
DESCRIPTION
31:3
///
Reserved
Do not modify. Read as zero.
2
BAM
BRGA Mode of Operation
Selects between the Timer Mode or the Baud
Range Generator Mode.
0 = Timer Mode; input clock source is always the system clock.
1 = Baud Rate Generator Mode.
1:0
///
Reserved
Read as zero.