AR-M207 M165 M162 SIMULATIONS 7-36
48
01
Main/sub scanning magnification ratio adjustment
Used to adjust the magnification ratio in the main scanning (front/rear) direction and the sub scanning
direction.
When this simulation is executed, the selection window of the adjustment items and the current set value
are displayed
The adjustment value is in the range of 1 - 99. (Default: 50).
When the adjustment value is increased by 1, the ratio is increased by 0.1%.
Select an adjustment item (mode) with the cross key and enter a desired value with 10-key.
When [OK] key is pressed, the entered value is saved to the EEPROM and the machine shifts to the copy
execution window.
After completion of copying, the machine returns to the adjustment value input window.
When [START] key is pressed instead of [OK] key, the machine shifts to the copy execution window and
performs copying.
Main
code
Sub
code
Contents
Remark
Sim48-1 COPY MAG.
1:F-R
2:SCAN
[ 1- 99]
50
50
50
(Adjustment item selection window)
Display text array
: Adjustment mode
1: F-R
: Main scan direction magnification
ratio (OC/CR)SPF)
2: SCAN
: Sub scan direction magnification ratio (OC)
Ready to copy.
S
100%
8 1/2
11
(Copy start window)
Copies in progress.
S
100%
8 1/2
11
(Copy execution window)
Adjustment
item selection
window
Copy start
window
Copy execution
window
OK
BACK
START
START
End of copy execution
[07]SIMULATIONS.fm 36