AR-M207 M165 M162 SIMULATIONS 7-22
26
30
CE mark conformity control ON/OFF
Used to set Yes/No of CE mark conformity.
When this simulation is executed, the current set value is displayed. Enter a value with 10-key and press
[OK] key or [START] key. The set value is saved to EEPROM and the machine returns to the sub code input
window.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
Default:
1 (ON)
31
Auditor mode exclusive setup
Used to set whether paper feed is allowed from the manual paper feed tray of not when the auditor is set to
the coin vendor mode.
* When this setting is set to ON, if the auditor mode is the coin vendor mode and the standard tray setting is
set to the manual paper feed tray, the standard tray setting is set to the main tray.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
Default:
1 (ON)
36
Cancel of stop at maintenance life over
Used to set YES/NO of cancel of stop when the maintenance counter life is over.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
Default:
1 (Stop cancel)
37
Cancel of stop at developer life over
Used to set YES/NO of cancel of stop when the developer counter life is over.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
39
Memory capacity check
Used to check the capacity of the image memory (SDRAM) installed to the MCU PWB and the capacity of
the IMC compression memory.
There are two kinds of the displayed image memory capacity: 16MB and 32MB.
The standard capacity of the IMC compression memory is 16B.
* It is not displayed when IMC is not installed.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
Main
code
Sub
code
Contents
Remark
Sim26-30 CE MARK
1:CE MARK CTRL
0=OFF
1=ON
[ 0-1]
Code: Setting
0 : CE mark support control OFF (*Default of 100V series)
1 : CE mark support control ON (*Default of 200V)
0
0
Sim26-31 AUDITOR
1:AUDITOR
[ 0-2]
Code: Setting
0 : Exclusive setting OFF (Manual paper feed enable)
1 : Exclusive setting ON (Manual paper feed disable) (Default)
2 : Exclusive setting OFF (Manual paper feed enable) + A3/WLT charge
1
1
Sim26-36 MAINTESTOP
1:MAINTE OVER
[ 0-1]
Code: Setting
0 : Stop
1 : Stop cancel (Default)
1
1
Code: Setting
0 : Stop
1 : Stop cancel (Default)
Sim26-37 DEVE STOP
1:DEV LIFE OVER
[ 0-1]
1
1
Sim26-39 MEMORY CHK
MCU
: 32Mbyte
IMC
: 16Mbyte
[07]SIMULATIONS.fm 22
ページ
2004年11月17日 水曜日 午後12時11分