AR-M207 M165 M162 SIMULATIONS 7-5
02
08
SPF paper feed solenoid operation check
Used to drive the SPF paper feed solenoid (PSOL) 20 times in the cycle of 500msec of "ON" and 500msec
of "OFF." After completion of the process, the machine returns to the sub code input window.
When [Interruption] key is pressed, the machine returns to the sub code input window.
When [CA] key is pressed, the machine exits the simulation mode.
09
RSPF reverse solenoid operation check
Used to drive the SPF reverse solenoid (RSOL) 20 times in the cycle of 500msec of "ON" and 500msec of
"OFF." After completion of the process, the machine returns to the sub code input window.
When [Interruption] key is pressed, the machine returns to the sub code input window.
When [CA] key is pressed, the machine exits the simulation mode.
10
RSPF paper exit gate solenoid operation check
Used to drive the SPF paper exit gate solenoid (GSOL) 20 times in the cycle of 500msec of "ON" and
500msec of "OFF." After completion of the process, the machine returns to the sub code input window.
When [Interruption] key is pressed, the machine returns to the sub code input window.
When [CA] key is pressed, the machine exits the simulation mode.
11
SPF PS release solenoid operation check
Used to drive the SPF PS release solenoid (CLH) 20 times in the cycle of 500msec of "ON" and 500msec of
"OFF." After completion of the process, the machine returns to the sub code input window.
When [Interruption] key is pressed, the machine returns to the sub code input window.
When [CA] key is pressed, the machine exits the simulation mode.
03
02
Shifter/job separator sensor status display
Used to monitor the sensors related to the shifter and the job separator and display the sensor status on the
LCD. An active sensor is highlighted.
* Displayed only when the job separator is installed except for SFTH.
Main
code
Sub
code
Contents
Remark
Sim2-8 SPUS CHECK
PRESS OK KEY
EXEC
Sim2-8 SPUS CHECK
EXEC
OK/START Key
(Initial window)
(Execution window)
Sim2-9 SPFS CHECK
PRESS OK KEY
EXEC
Sim2-9 SPFS CHECK
EXEC
OK/START Key
(Initial window)
(Execution window)
Sim2-10 SGS CHECK
PRESS OK KEY
EXEC
Sim2-10 SGS CHECK
EXEC
OK/START Key
(Initial window)
(Execution window)
Sim2-11 CLH CHECK
PRESS OK KEY
EXEC
Sim2-11 CLH CHECK
EXEC
OK/START Key
(Initial window)
(Execution window)
Sim3-2 SENSOR
SFTHP
TRYF
JSUP
TRYD
JSDL
Displayed name
:Sensor name
SFTHP
:Shifter home position sensor
JSUP
:Job separator upper limit sensor
JSDL
:Job separator lower limit sensor
TRYF
:Tray full sensor
TRYD
: Paper exit sensor
[07]SIMULATIONS.fm 5
ページ
2004年11月17日 水曜日 午後12時11分