AR-M207 M165 M162 SIMULATIONS 7-28
44
34
Transfer current setting
Used to set the transfer current value. When this simulation is executed, the list of modes and the current set
value are displayed on the LCD.
Select a set item with the cross key and enter a set value with 10-key. Press [OK] key or [START] key, and
the set value is saved in the EEPROM.
The setting range is 90µA - 360µA. The calculation formula is "Set value x 10 (µA)."
For example, in order to set the transfer current value to 200µA, set the adjustment value to "20."
[ ]: Default
* Small size paper means A4R (Letter R) width or less.
* When selecting the special size of tray, the normal size width setting is made.
Default:
21(NML R, SML R)
22(NML F, SML F,
BYPASS)
40
Setting of rotation time before toner supply
Used to set the time from starting rotation of the main motor to starting toner supply when initializing after
turning on the power.
[1] - [99] (Default : [8] (Unit: sec))
Enter a set value with10-key and press [START] key. The set value is saved in theEEPROM and the
machine returns to the sub code input window.
Default:
8sec
46
01
Copy density adjustment(300dpi)
Used to set the copy density foe each exposure mode.
When this simulation is executed, the list of the setting items and the current set value are displayed.
Select an item to be changed with [ ] and [ ] keys and enter the adjustment value with 10-key.
The setting range is 1 - 99.
When [
] or [
] key is pressed, the page is changed,.
Enter the adjustment value with 10-key and press [OK] key. The entered value is saved in the EEPROM and
the machine shifts to the copy window.
Sample copying can be performed during the simulation
Main
code
Sub
code
Contents
Remark
Sim44-34 TC
ADJ.
1:NML F
2:NML R
3:SML F
1/2 [ 9- 36]
22
21
22
22
Sim44-34 TC
ADJ.
4:SML R
5:BYPASS
2/2 [ 9- 36]
21
22
22
Display mode
: Setting mode
NML F
: Normal size paper (Front) [22]
NML R
: Normal size paper (Back) [21]
SML F
: Small size paper (Front) [22]
SML R
: Small size paper (Back) [21]
BYPASS
: Manual paper pass [22]
Sim44-40 TONER
1:ROTATE TIME
[ 1- 99]
8
8
Sim46-1 EXP LEVEL
1:AE
2:TEXT
3:PHOTO 1
1/2 [ 1- 99]
50
50
50
50
Sim46-1 EXP LEVEL
4:PHOTO 2
5:TEXT(TS)
6:AE(TS)
2/2 [ 1- 99]
50
50
50
50
Window display
: Adjustment mode
1:AE
: AE MODE (300dpi)
2:TEXT
: TEXT MODE (300dpi)
3:PHOTO 1
: PHOTO MODE (Error diffusion)
4:PHOTO 2
: PHOTO MODE (Dither)
5:TEXT (TS)
: TS MODE (TEXT) (300dpi)
6:AE (TS)
: TS MODE (AE) (300dpi)
[07]SIMULATIONS.fm 28
ページ
2004年11月17日 水曜日 午後12時11分