AR-M207 M165 M162 SPECIFICATIONS 2-8
(3) Scanner function Specification
a. PUSH Scan(USB)
b. PULL Scan(TWAIN)
c. Network Push scan(When the network box is installed)
Paper
Output Tray
Selection
Upper Tray
Center Tray
When the job separator is
installed, selection is made
between the upper stage
and the center stage of the
paper exit tray.
Advanced Print Quality
Draft
Normal
Photo
Draft/Normal (only for
Windows 9x, Me)
Image
Adjustment
Yes/No
Contrast and brightness of
images are adjusted. For
Windows NT4.0/2000/XP,
enable only for the Photo
mode of Print Quality.
Brightness
0 - 100%
The image brightness is
adjusted by moving the
scale from 0 to 100. The
illustration image on the
left upper corner of the
display is changed.
Contrast
0 - 100%
The image contrast is
adjusted by moving the
scale from 0 to 100. The
illustration image on the
left upper corner of the
display is changed.
Pured Black
print
Yes/No
A document made by a
CAD program is printed in
black to provide clear print
of color line images and
texts.
Water-
marks
Watermarks
None/TOP
SECRET/
CONFIDENTI
AL/DRAFT/
ORIGINAL/
COPY
User Setting
Add/Update/
Delete
Position
Center
X: ± 50
Y : ± 50
Size
6 - 300
Angle
± 90
Grayscale
0 - 255
Edit Font
Yes
On First Page
only
Yes/No
Function
Content
Supported OS
Win98/Me/2000/XP
Hardware
environment
(System)Must meet the operating conditions of
each OS.
(HDD)8MB or above: 100MB or above
recommendable
(Monitor)800 x 600 dots or above, 256 colors or
more must be displayed.
(Other)USB port(1.1 or 2.0)
Selectable
destination
SharpDesk/E-mail software/Fax software/OCR
software/MS Word
USB TWAIN
Supported OS
Win98/Me/2000/XP
Hardware
environment
(System)Must meet the operating conditions of
each OS.
(HDD)8MB or above: 100MB or above
recommendable
(Monitor)800 x 600 dots or above, 256 colors or
more must be displayed.
(Other)USB port
Duplex scan
Yes
Color mode
Black and white(Simple binary)/Black and
white(Error diffusion)/Gray scale/Full color
Resolution
Pull: 600 x 600dpi
Emulation: 50-9600dpi
Custom: 50-9600dpi
Preview function
Yes
Zoom preview
function
Yes
Rotation scan
Yes (90 degrees/180 degrees/270 degrees)
Brightness/
contrast
adjustment
Auto/Manual(-100 - +100)
Gamma
adjustment
Yes
Color matching
None/Printer/CRT/LCD display/ICM
Edge emphasis
None/Normal/Strong/Blur
Black/white
reverse
Yes
Light source
selection
Yes (Red/Green/Blue/White)
Threshold value
setting
Auto/Manual(1 - 254)
Void area addition Available(Top/End edge = 2.5mm /Left/Right =
3.0mm)
Set contents save
Yes
Selectable
destination
Scan to E-mail/FTP/Desktop
Destination
selection method
Address book
LDAP retrieval/selection
Ad-Hoc(10-key input)
[02]SPECIFICATIONS.fm 8
ページ
2004年11月16日 火曜日 午後3時23分