AR-M207 M165 M162 ADJUSTMENT 6-4
<Adjustment specification>
c.Rear edge void adjustment (SIM50-1, SIM50-19)
1) Set a scale as shown in the figure below.
2) Set the document size to A4 (8.5" x 11"), and make a copy at 100%.
3) If necessary, perform the following adjustment procedure.
4) Execute SIM50-01 and select “DEN-B” with the arrow keys.
The currently set adjustment value is displayed.
5) Enter the set value and press the start key. The correction value is
stored and a copy is made.
<Adjustment specification>
d. Paper off center adjustment (SIM50-10)
1) Set a test chart (UKOG-0089CSZZ) on the document table.
2) Select a paper feed port and make a copy. Compare the copy and
the test chart. If necessary, perform the following adjustment
procedure.
3) Execute SIM 50-10. After completion of warm-up, shading is
performed and the currently set off center adjustment value of each
paper feed port is displayed.
4) Enter the set value and press the start key. The correction value is
stored and a copy is made.
<Adjustment specification>
e.Side edge void area adjustment (SIM26-43)
Note: Before performing this adjustment, be sure to check that the paper
off center adjustment (SIM 50-10) is completed.
1) Set a test chart (UKOG-0089CSZZ) on the document table.
2) Select a paper feed port and make a copy. Compare the copy and
the test chart. If necessary, perform the following adjustment
procedure.
3) Execute SIM 26-43 and set the density mode to SIDE VOID (L),
SIDE VOID (R).
The currently set adjustment value is displayed.
4) Enter the set value and press the start key. The correction value is
stored.
<Adjustment specification>
Adjustment mode
SIM
Display
text
array
Set value Spec value
Set
range
SPF image lead
edge position
(1st print surface)
SIM
50-6
SIDE1
1 step:
0.1mm
shift
Lead edge
void:
1 - 4mm
Image loss:
3mm or
less
1 - 99
Mode
SIM
Display
text array
Set value
Specifi-
cation
Set
range
Rear edge void
SIM
50-1
DEN-B
1 step:
0.1mm shift
4mm or
less
1 - 99
A4(8.5" x 11")
Paper rear edge
Scale image
Paper rear edge
Void amount (Standard value: 4mm or less)
Adjustment
mod
SIM
Display
text array
Set value
Specifi-
cation
Set
range
Tray1
SIM
50-10
TRAY1
Add 1:
0.1mm shift
to R side.
Reduce 1:
0.1mm shift
to L side.
Single:
Center
±2.0mm
1 - 99
Tray2
TRAY2
Tray3
TRAY3
Tray4
TRAY4
Manual paper
feed tray
BYPASS
Duplex
(Second print
surface)
DUPLEX
Adjustment
mode
SIM
Display
text array
Set value
Specifi-
cation
Set
range
Side void (left)
26-43
SIDE
VOID (L)
1 step:
0.5mm shift
0.5 - 4mm 1 - 99
Side void (right)
SIDE
VOID (R)
Sim50-10 PRT. CENTER
1:TRAY1
2:TRAY2
3:TRAY3
1/2 [ 1- 99]
50
50
50
50
Sim50-10 PRT. CENTER
4:TRAY4
5:BYPASS
6:DUPLEX
2/2 [ 1- 99]
50
50
50
50
Sim26-43 SIDE VOID
1:SIDE VOID(L)
2:SIDE VOID(R)
[ 0- 10]
3
3
3
[06]ADJUSTMENT.fm 4
ページ
2004年11月12日 金曜日 午後2時13分