User’s guide
HRP/D
-
36
-
HS
Installation and removal of units
12
12.3
TIMER/SWITCH UNIT
Installation and removal of these units is the same as for the
control units, except for undoing the wiring
Undoing the wiring
The plugs are not interchangeable, as each one is unique to its
panel socket. A wrong connection can never be made
1.
Disconnect the compressed air, and make sure the main
power switch is off.
2.
The round black plugs have a bayonet fitting. Remove
them by turning the ring one turn to the left and pulling
out the plug. The small line on the ring is then lined up
with the screw.
3.
The bottom plug on the timer unit can be removed by
pressing in the small stop.
4.
To remove the white plug, press down the white stop on
the top of the plug with a screwdriver.
5.
Remove the flat plug simply by pulling it out.
6.
Disconnect the cables connected to the Water Separator,
and remove the Air tubes from the unit.
12.4
MAIN SWITCH BOX
12.4.1
Removal
1.
Remove the solid core strips by unscrewing the socket
head screws. (Use socket screw key
no. 6
).
2.
Slide the heating elements forward (see Section
8
).
Bayonet fitting
2
3
Small stop
Содержание HRP/D
Страница 1: ...User s Guide English Plastic bending machine HRP D...
Страница 5: ...User s guide HRP D 4 HS Equipment 51 H Service and warranty 53...
Страница 45: ...User s guide HRP D 44 HS Annex DIAGRAM CONTROL UNIT B...
Страница 46: ...User s guide HRP D 45 HS Annex DIAGRAM TIMER UNIT C...
Страница 47: ...User s guide HRP D 46 HS Annex DIAGRAM SWITCH UNIT D...
Страница 48: ...User s guide HRP D 47 HS Annex DIAGRAM PNEUMATIC SYSTEM E...
Страница 49: ...User s guide HRP D 48 HS Annex DIMENSIONS F 1300 3390 1550 1720...