- 26 -
303 Data transmission mode
00
00: Simplex / Stream Mode
01: Duplex / Command Mode
02: Print Mode
03: Modbus(RTU)
304
“Check-Sum” under command mode
00
00: Disuse
01: Use
305
Data Format under Stream Mode
00
00: Format 1
01: Format 2
02: Format 3
03: Format 4
306
Date transference under stream mode
00
00: Continuously
01: Single time on every steady state
02: Single time(finish weighing process)
03: When input “PRINT” key
307
Modbus Transmit Data MSB/LSB location
00
00: Standard
01: Change
352
Print Format Setting
00
00: Continuous Print
01: Single Print
354
Print Output Delay Time Setting
00
00~09 (Unit: 1 sec)
355
Paper Withdraw Rate setting
(After Continuous/Single Print)
00
00~09 (Unit: 1 line add)
356
Paper Withdraw Rate setting
(After SUB/GRAND Total Print)
00
00~09 (Unit: 1 line add)
358
Grand total data delete
(After SUB/GRAND Total Print)
00
00: Disuse
01: Use