Weighing Mode 3. (“HOLD” input Mode)
– Auto HOLD input / Auto HOLD Reset mode (Under F55-01 setting)
1. Set Value Condition : Over Set value > Under Set value
※
If the setting conditions are not satisfied,
“E”
symbol displayed and you can process the weighing.
2. Weighing Judgment – Please set “F19-01(Peak Hold).
After “HOLD(Peak)” key input, indicator will delay the judgment during “t3”.
After “t3” set time, indicator will judge the weight and output “Over” / “Under” / “Pass” relay.
※
Auto “HOLD” Input : The Weight is over than “Empty” Range, “HOLD” will be set automatically and
start tracking “Peak” value during “t3” period.
※
Auto “HOLD Reset” Input : After finishing Weight judgment, weigh will be lower than “Empty” Range,
“HOLD” will be reset automatically.
※
From Weight judgment relay output to Empty relay output, indicator will hold finished weight judgment
data on the main display.
4. Output Relay
Output
Contents
Output
Contents
Under(1)
Less than “Under” set, “ON”
N.G(4)
Under/Over relay output, “ON”
Over(3)
More than “Over” set, “ON”
Empty(5)
Within the Empty Range “ON”
Pass(2)
Under set
≤
Current Weight
≤
Over set
Weight
EMPTY
HOLD Input
UNDER
OVER
PASS
N.G
Empty
OVER Range
Under Range
OVER
UNDER
PASS
t3
t3
t3
t4
t4
t4
t5
t5
Output
1
Output
5
Output
3
Output
2
Output
4