- 30 -
5-6. F-Function Detailed information
■
General Function Setting
(
●
Factory default set value)
Weighing Data Save Method Selection
(Apply on Accumulated weighing count/weight)
●
0
Manual Save Mode (Save when
“Print”
key input)
F01
1
Automatic Save Mode
(Save when
“Weight Judge Finish Relay output”
)
1. F01-00, F38-00 setting (Manual Save mode + Manual Print mode)
Weighing Judgment data will be saved when
key input. And Print will be output simultaneously.
So,
the saved data and printed data is same.
If the
key is not input, Finished Weighing Data will not be saved and Printed.
2. F01-00, F38-01 setting (Manual Save mode + Auto Print(When Weight Judgment relay
output)mode)
When
“
Weight Judgment Finish Relay
”
output, Print will be done automatically., But weighing
Judgment data will not be saved automatically. If you want to save
“
Weighing Judgment data
”
, you
have to press
key separately.
※
Caution
Under this setting, there might be some difference between “Saved Data” and “Printed Data”.
3. F01-01, F38-00 setting (Automatic Save(When Weighing Judgment relay output) + Manual
Print mode)
When
“
Weighing Judgment Finish relay
”
output, the Judgment data will be saved automatically, but
this data will not be printed out. If you want to print out
“
Judgment data
”
, you have to press
key separately.
※
Caution
Under this setting, there might be some difference between “Saved Data” and “Printed Data”.
4. F01-01, F38-01 setting (Automatic Save(When Weighing Judgment relay output) + Automatic
print(When Weighing Judgment relay output) mode