- 34 -
Zero key Operation Range selection
0
Activated within 2% of Max. Capacity
1
Activated within 5% of Max. Capacity
●
2
Activated within 10% of Max. Capacity
F08
3
Activated within 20% of Max. Capacity
Tare key Operation Range selection
0
Activated within 10% of Max. Capacity
1
Activated within 20% of Max. Capacity
●
2
Activated within 50% of Max. Capacity
F09
3
Activated within 100% of Max. Capacity
“Key TARE” Operation Selection
●
0
Key TARE Function Not Use.
F10
1
Key TARE Function Use
※
Key TARE Function : You can set TARE value with No. keys, without weight.
※
To input Key TARE value(F10-01 setting),
Press
“TARE”
key, and input
“target TARE value”
with No. keys and press
“ENTER”
.
External Input Selection
Set Value
Input 1
Input 2
Input 3
Input 4
0 TARE
TARE
RESET
ZERO
1 ZERO
TARE /
TARE RESET
PHOTO
SENSOR
●
2 ZERO
TARE /
TARE RESET
HOLD HOLD
RESET
F11
3 ZERO TARE TARE
RESET
HOLD /
HOLD RESET
※
The Input signal pulse must be more than 1msec.