- 37 -
HOLD Selection
●
0
Sample HOLD : Hold the weight value, when the “HOLD” key input
F19
1
Peak HOLD : Hold the “PEAK” value of weight, during the set time
(Under F21-02 setting, must be set PEAK HOLD).
■
Relay Output Mode Setting
Weighing Mode selection
●
1
PHOTO SENSOR INPUT MODE
2
HOLD KEY INPUT MODE
F21
3
SIMPLE COMPARISON MODE 1.
4
SIMPLE COMPARISON MODE 2.
※
Each set value were pre-set from Factory, as Over(3000), Under(2000), Count(0000).
Relay output Mode(Each weighing Mode)
Weighing Mode
Output1
Output2 Output3 Output4 Output5
Output6
1 PHOTO
SENSOR UNDER PASS OVER N.G EMPTY N.A
2 HOLD
MODE UNDER PASS OVER N.G EMPTY N.A
3
SIMPLE
1..
UNDER PASS OVER N.G EMPTY N.A
SIMPLE
2.
UNDER PASS OVER N.A EMPTY N.A