Digital Weighing Indicator
SI 4100
G
TG[ZGTG
1
+9V
LSB
0
1 2 3 4 5
MSB
6
0 -9V
6-1-4 Data Format(1) : ID Number will not be transferred. (Refer “F-function 37”)
,
,
+/-
Including Decimal
point
k g
CR
LF
Header 1.
Header 2.
Data Byte ( 7 or 8 byte )
(F38 setting)
Unit
ཛ
Header 1. : OL : Over Load, Under Load
ST : Display weight “Steady”
US : Display “Un-Steady”
ཛྷ
Header 2. : NT : Net-Weight
GS : Net-Weight, under TARE
ཝ
Data Bit(Number) 2B(H) : “+” Plus
2D(H) : “-“ Minus
2D(H) : “ “ Space
2E(H) : “.” Decimal Point
ཞ
Unit : kg, g, t
6-1-5 Data Format(2) : ID Data Transference (Refer “F-function 18, 37)
,
,
,
+/-
Including Decimal point
CR
LF
ID No.
Header 1
Header 2
Data Byte
( 7 or 8 byte )
(F38 setting)
Unit
ཛ
Header 1. : OL : Over Load, Under Load
ST : Display “Steady”
US : Display “Un-Steady”
Start Bit
Data Bit
Parity Bit
Stop Bit