Digital Weighing Indicator
SI 4100
G
TG[XGTG
G
Serial Communication Speed selection
F61
0
2,400bps
1
4,800bps
ᕢ
2 9,600bps
3
14,400bps
4
19,200bps
5
28,800bps
6
38,400bps
7
57,600bps
8
76,800bps
9
115,200bps
DATA Transference Method selection
F62
ᕢ
0
Simplex Mode / Stream Mode
1
Duplex Mode / Command Mode
Print port selection (Under F62-01 setting, only)
F63
ᕢ
0
Same port as using for Command Mode.
1
The other port.
“Check-Sum” detection selection (Under F62-01 setting, only)
F64
ᕢ
0
Check-Sum data will not be included on transferred data.
1
Check-Sum data will be included on transferred data.
Serial Port Application Selection (Under F62-00 setting, only)
F65
ᕢ
0
DATA Transference purpose
1
Printing purpose (Serial Printer)
DATA Transference Mode selection (Under F62-00, F65-00 setting, only)
F66
ᕢ
0
Stream Mode : Weighing Data will be transferred continuously.
1
Finish Mode : When Finish Relay output, only 1 time transferred.
2
Manual Mode : When “Print” key input, 1 time transferred.
DATA Transference Format selection(Under F62-00, F65-00 setting, only)
F67
ᕢ
0 Format
1.
1
Format 2. (Format 1 + ID No.)
2
CAS
Format
Print Mode selection (Under F62-00, F65-01 setting, only)
F68
ᕢ
0
Manual Print : Whenever “Print” key input.
1
Auto Print : When Finish relay output, automatically print.
Create PDF
files without this message by purchasing novaPDF printer (
http://www.novapdf.com
)