Digital Weighing Indicator
SI 4100
G
TG[_GTG
6-4. Analog Output Interface (Option 02 : 0~10V Output)
This Option card converts weight value to Analog Voltage output(0~10V) and transfers to external
devices(Recorder, P.L.C), controlled by voltage output.
6-4-1. Specification
ཛ
Output Voltage : 0~10V DC output
ཛྷ
Accuracy : More than 1/1,000
6-4-2. Circuit
ଖ
This Voltage output is proportioned on weight calibration and outputs 0~10V.
6-4-3. Output Adjustment
ཛ
This output is adjusted as when the weight is “Zero”, output is 0V and When the weight is “Full capacity”,
output is 10V.
ཛྷ
If you need additional adjustment, please adjust with “VR1(Zero)”, “VR2(Span) on the Analog Output PCB.
ଖ
Remark
This Analog option card converts Displayed weight value(Micro-process data) to analog value on D/A
Converter(Digital to Analog converter)
This D/A Converter has Max. 1/4,000 accuracy, so this output is not suitable for high accuracy application, like
more than 1/3,000.
6-4-4. Connecter (9pin, “D-type” female)
9 pin D-type connector(Female)
Terminal Block (3 pin)
1 : HI(+), 5 : (-)
G
G
For 0~5VDC or 1~5VDC analog output, please inform when you inquiry.
ଖ
Create PDF
files without this message by purchasing novaPDF printer (