G
TG[WGTG
G
SPAN Calibration Value Check
F89
X.X.X.X.X.X.
Span Calibration Value Check
Under F-function mode, enter “
”, “
” key and press “
”.
After checking the value and press “
” to exit
ଖ
If you have difficulty to process Calibration again, the best way to matching the net
weight and display weight is doing Calibration process once again.
DATE Check / Change
F90
Check Current DATE data or you can Change to new date
TIME check / Change
F91
Check Current TIME data or you can Change to new date
Set the pass word and change
F95
You can set the pass word and change it.
How to set : When “P-W” is displayed ,input the password .
1) If “1” display, input password (4 numbers)
2) If “2” display, recheck the password
“0000” is saved as basic password.
When setting password you cannot start “SETUP” mode without password, do not forget your password.
Program & Hard ware Version Check
F98
Check the Program & Hard ware version (H/W : X.XX, S/W : X.XX.X)
Production DATE Check
F99
Check the Product’s Production Year and Month.
■ Communication Mode setting (Serial Port 2. - Optional Serial port)
Parity Bit selection Mode
F60
ᕢ
0
DATA Bit (8 Bit)
STOP Bit (1 Bit)
Parity Bit (Non)
1
DATA Bit (7 Bit)
STOP Bit (2 Bit)
Parity Bit (Non)
2
DATA Bit (7 Bit)
STOP Bit (1 Bit)
Parity Bit (Even)
3
DATA Bit (7 Bit)
STOP Bit (1 Bit)
Parity Bit (Odd)
4
DATA Bit (8 Bit)
STOP Bit (2 Bit)
Parity Bit (Non)
5
DATA Bit (8 Bit)
STOP Bit (1 Bit)
Parity Bit (Even)
6
DATA Bit (8 Bit)
STOP Bit (1 Bit)
Parity Bit (Odd)