3 Using the system
│
25
3.3.2
Adjusting the pipe data
Pipe sections are characterised by the following features:
●
Length of pipe
●
Diameter of pipe
●
Pipe material
●
Sound velocity in the pipe section
Adjoining pipe sections in a measuring section can have different
pipe data.
New pipe sections are automatically assigned values from the
Pipe data (Default)
. The values must then be adjusted according
to the conditions on the ground.
For more detailed information about the selection options and
value ranges, please refer to section 4.3.3 on page 56.
The
Pipe sections
menu is open.
1. Tap the pipe section for which you want to adjust the pipe
data. The pipe section will be highlighted in blue.
2. Adjust the pipe data.
3. Apply the settings by pressing
Confirm
. The receiver will
switch back to the main view.
Note:
After a sound velocity measurement (section 3.6.3), the
Sound
velocity
symbol is displayed next to the numerical value in the
Pipe sections
menu under
Sound velocity
.
If you manually adjust the preset sound velocity, the
Manual
sym-
bol is displayed next to the numerical value in the
Pipe sections
menu under
Sound velocity
.
3.4
Performing a measurement
Each measurement must be started manually and stopped at a
suitable time.
Once a measurement has been stopped, it can be saved, con-
tinued or repeated.