2 SeCorr system
│
13
Fig. 12:
Pipe sections
button,
here:
Measuring section with three pipe
sections
Top image:
Before starting a measurement.
Bottom image:
After starting/stopping a measurement
The
Pipe sections
menu is opened by pressing the
Pipe sec-
tions
button. The following settings can be made in this menu:
●
Number of pipe sections in a measuring section
●
Pipe data for every pipe section
−
Material
−
Diameter
−
Length
−
Sound velocity
For more detailed information about configuring the pipe sec
-
tions, please refer to section 3.3 on page 22.
Filter
The
Filter
button displays the following information:
●
Correlation curve
●
Marker
Corresponds to the leak position.