12
Technical data
EtherNet/IP™ scanner communication protocol
Manual – MOVI-C
®
CONTROLLER progressive UHX65A-M
54
Parameter
Description
PROFINET specification
•
Implemented acc. to V2.3 ED2 MU3
•
Legacy startup acc. to PROFINET specifica-
tion V2.2 supported
Baud rate
100 Mbit/s full duplex
Data transport layer
Ethernet II, IEEE 802.3
Configuration file
Maximum 1 megabyte
Limitations
The following functions are not supported:
•
"RT over UDP"
•
"Multicast communication"
•
DHCP server
•
DHCP client
•
Shared device
•
MRP manager
•
MRPD (Media Redundancy for Planned Du-
plication)
•
IRT planning through the PROFINET IO
controller
•
Sync slave
•
Multiple MRP managers
•
Multiple sync masters
The following functions are subject to restric-
tions:
•
Only one fragmented acyclic service at a
time
•
Only one DCP service at a time
12.2
EtherNet/IP™ scanner communication protocol
Parameter
Description
Maximum number of EtherNet/IP™
connections
64 connections for implicit and explicit connec-
tions
Maximum number of all cyclic input
data
5712 bytes
Maximum number of all cyclic out-
put data
5760 bytes
Maximum number of cyclic input
data
504 bytes per slave per telegram
Maximum number of cyclic output
data
504 bytes per slave per telegram
IO connection type
Cyclic, minimum 1 ms (depending on the num-
ber of connections used and the number of in-
put and output data used)
26881144/EN – 02/2022