8
Startup with PROFINET
Connecting the fieldbus and engineering PC
Manual – MOVI-C
®
CONTROLLER progressive UHX65A-M
26
8
Startup with PROFINET
8.1
Connecting the fieldbus and engineering PC
The engineering PC can be connected to the controller in several ways:
•
Connection via standard engineering interface X80 (recommended)
•
Connection to the fieldbus network (e.g. PROFINET) via fieldbus interface X40/
X41
Ethernet
X80
X40/
X41
35952010251
8.2
Connection via standard engineering interface X80 (recommended)
The standard engineering interfaces have the following IP address settings in the de-
livery state:
•
IP address: 192.168.10.4
•
Subnet mask: 255.255.255.0
•
Standard gateway: 192.168.10.4
•
Connect the MOVI-C
®
CONTROLLER UHX65A-M to the engineering PC via the
standard engineering interface X80 using an RJ45 Ethernet connection cable. The
illustration is a schematic representation of the device topology using the
MOVI-C
®
CONTROLLER progressive UHX65A as an example.
8.3
Connection to the fieldbus network via fieldbus interface X40/X41
Connect the MOVI-C
®
CONTROLLER UHX65A-M to the fieldbus network (e.g.
PROFINET or EtherNet/IP™) via the fieldbus interface X40 or X41 using an RJ45 Eth-
ernet connection cable.
26881144/EN – 02/2022