10
Technical data and dimension sheets
Technical data
Operating Instructions – MOVI-C
®
FIELD CONTROLLER standard/advanced
137
Electronics cover (controller)
MOVI-C
®
FIELD CONTROLLER
MFC1..
Electronics cover (controller)
FHX25A-N
FHX25A-E
FHX45A-N
FHX45A-E
Memory
•
Retain data: 32 kB
•
Retain persistent: 2 kB
•
Data memory: 6 MB
•
Program memory: 2 MB
for application, including libraries
OMH25A or OMH45A
SD
memory card in the SD card
slot
• PC-readable
• Contents:
– Firmware
– IEC program
– Application data
•
512 MB memory
Installation location
MOVI-C
®
FIELD CONTROLLER
MFC1..
Electronics cover (controller)
FHX25A-N
FHX25A-E
FHX45A-N
FHX45A-E
Ambient temperature
See chapter "Environmental conditions"
Degree of protection
IP
Standard: IP65 according to EN 60529 (housing closed and all
cable bushings sealed)
Pollution class
2 in accordance with IEC 60664-1
Overvoltage category
III in accordance with IEC 60664-1
Installation altitude
h
Up to h ≤ 1000 m: without restrictions
The following restrictions apply to altitudes > 1000 m:
•
From 1000 m to maximum 3800 m: I
N
reduction by 1% per
100 m
•
From 2000 m to maximum 3800 m: To maintain protective
separation and the air gaps and creepage distances accord-
ing to EN 61800‑5‑1, an overvoltage protection device must
be connected upstream to reduce the overvoltages from ca-
tegory III to category II.
Proof of mechanical strength
3M7/5M2 according to DIN EN 60721-3-3/5
26872137/EN – 12/2021