10
Technical data and dimension sheets
General information
Operating Instructions – MOVI-C
®
FIELD CONTROLLER standard/advanced
136
10.2
General information
10.2.1
Air admission and accessibility
When installing the driven machine, make sure there is enough space in axial and ra-
dial direction for a sufficient supply of cooling air and unobstructed heat dissipation.
10.3
Technical data
10.3.1
General technical data
Input
MOVI-C
®
FIELD CONTROLLER
MFC1..
Electronics cover (controller)
FHX25A-N
FHX25A-E
FHX45A-N
FHX45A-E
Voltage supply for connected drive units
Nominal supply voltage AC
(to EN 50160)
U
line
3 × AC 380 V – 500 V
Nominal line current AC
I
line
Corresponds to output current
≤ 24 A (for MFC1..
without
switch disconnector)
≤ 20 A (for MFC1..
with
switch disconnector)
Line frequency
f
line
50 – 60 Hz ± 10%
Voltage supply for electronics cover (controller)
Nominal voltage DC
(according to IEC 61131-2)
V
DC
24 V (-15% – +20%)
Nominal current DC
I
MAX
500 mA
Output
MOVI-C
®
FIELD CONTROLLER
MFC1..
Electronics cover (controller)
FHX25A-N
FHX25A-E
FHX45A-N
FHX45A-E
Output voltage
V
OUT
Matches the nominal line voltage V
line
Output frequency
f
OUT
Matches the line frequency I
line
Nominal output current
I
N
≤ 24 A (for MFC1..
without
switch disconnector)
≤ 20 A (for MFC1..
with
switch disconnector)
26872137/EN – 12/2021