8
Service
Device replacement in MOVISUITE®
Operating Instructions – MOVI-C
®
FIELD CONTROLLER standard/advanced
125
8.6.3
Logging function
The MOVI-C
®
FIELD CONTROLLER has a logging function, for example, to track the
processing procedures in the event of an error. The logging function is disabled by de-
fault.
INFORMATION
To keep the write operations on the memory card low and in this way prevent a de-
fect, the logging function should not be activated permanently.
To activate the logging function, do the following:
1. On your engineering PC connected to the MOVI-C
®
FIELD CONTROLLER, open
the OMH memory card content using a file explorer.
2. Navigate to the "log" directory on the OMH memory card.
ð
The "log" directory contains the
LogConfig.Example.xml
file.
3. Rename the
LogConfig.Example.xml
file into
LogConfig.xml
.
ð
The logging function is now active.
26872137/EN – 12/2021