Structure of the PROFINET parameter channel
Parameterization via PROFIdrive Data Set 47
Query parameter response
The following table shows the coding of the READ.req user data including the
PROFINET header.
Positive response to "WRITE Parameter volatile"
Negative parame-
ter response
The following table shows the coding of a negative response of a MOVILINK
®
service.
Bit 7 is entered in the the response ID if the response is negative.
Service
READ. request
Description
API
0
Fixed setting = 0
Slot_Number
0
Random (is not evaluated)
Subslot_Number
1
Fixed setting = 1
Index
47
Index of the dataset for the parameter request; constant index 47
Length
240
Maximum length of response buffer in the master
Service
READ. response
Description
API
0
Fixed setting = 0
Slot_Number
0
Random (is not evaluated)
Subslot_Number
1
Fixed setting = 1
Index
47
Index of the dataset for the parameter request; constant index 47
Length
4
4 byte user data in response buffer
Byte
Field
Value
Description
0
0x01
Mirrored reference number from the parameterization
request
1
Response ID
0x40
Positive MOVILINK
®
response
2
0x00
Mirrored axis number; 0 = single axis
3
No. of parameters
0x01
1 parameter
Service
WRITE. response Description
API
0
Fixed setting = 0
Slot_Number
0
Random (is not evaluated)
Subslot_Number
1
Fixed setting = 1
Index
47
Index of the dataset for the parameter request; constant index 47
Length
8
8 byte user data in response buffer
Byte
Field
Value
Description
0
0x01
Mirrored reference number from the parameterization request
1
Response ID
0xC0
Negative MOVILINK
®
response
2
0x00
Mirrored axis number; 0 for single axis
3
No. of parameters
0x01
1 parameter
4
Format
0x44
Error
5
No. of values
0x01
1 Error code
6, 7
Error value
0x0811 MOVILINK
®
return code
e.g. error class 0x08, Add. code 0x11
(see section "MOVILINK
®
parameterization return codes for
PROFINET" on page 81)
0
0