![SEW-Eurodrive DFE32B PROFINET IO Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/sew-eurodrive/dfe32b-profinet-io/dfe32b-profinet-io_manual_1250328051.webp)
Manual – DFE32B Fieldbus Interface PROFINET IO
51
5
Startup procedure for the DFE32B option as gateway
Project Planning with PROFINET
Step 2: Configuring PROFINET
1. Start the control manufacturer's software to configure the hardware (e.g. STEP 7-
HWKONFIG).
2. Install the GSD file if necessary (
→
section "Preliminary work")
3. Check whether PC and control are located in the same subnetwork:
– Are the IP addresses of PC and CPU identical up to the lowest byte?
– Is the subnet mask identical?
4. Check whether a TCP/IP communication can be established with the controller.
5. Carry out the PROFINET configuration according to this manual.
– Assign PROFINET device name
– Assign IP configuration if necessary
– Perform process data configuration
– Load the project planning to the controller
6. The BUS FAULT LED of the DFE32B option is off when PROFINET is successfully
configured. Process data is now being exchanged.
7. Extend control program and set up process data exchange to DFx gateway.
8. Start MOVITOOLS
®
MotionStudio and open a new project. Set up "Ethernet" as
communication interface.
– Alternatively, MOVITOOLS
®
MotionStudio can be operated via serial communi-
cation with USB11A. Connect PC with DFx gateway.
9. Perform a unit scan. DFx gateway and all units installed at the SBus must now be
accessible if the MOVITRAC
®
B units have been configured beforehand.
10.Activate the DFx gateway via the mouse and start the "Monitor DFx Feldbus Gate-
way" tool via the right mouse button. Go to the Process data monitor window and
check whether the process data exchange between controller and gateway is work-
ing.
11.Switch on the supply voltage and enable MOVITRAC
®
B at the terminals (DI01=1).
Activate unit enable via control word 1 = 0x0006
– If MOVITRAC
®
B remains in "No Enable" condition, check terminal assignment
(parameter group P60x) and supply further binary inputs with DC 24 V if required.