Manual – DFE32B Fieldbus Interface PROFINET IO
41
5
Project planning for the PROFINET IO controller
Project Planning with PROFINET
Starting the con-
troller
Load the project planning in the SIMATIC S7 and start the module. The Error LED of the
controller should now go out.
The LEDs of the DFE32B option should have the following statuses:
• RUN LED: lights up green
• BUS FAULT LED: off
• Link/Activity LED: Flickering
If this is not the case, check the project planning, especially the device name and the IP
address of the node.
Application
example
8 MOVITRAC
®
B frequency inverters are to be operated at a variable speeds in this ex-
ample. The information between PLC and the individual inverters is exchanged via 3
process data.