4
Procedure after a replacement
Assembly and Installation Notes
4.9
Procedure after a replacement
4.9.1
MOVIDRIVE
®
B unit replacement
If you insert the memory card of the replaced MOVIDRIVE
®
B in the new MOVIDRIVE
®
B, the new unit is recognized by the PROFINET IO controller without any additional
measures.
There are no measures required if only the DFE32B option is replaced.
4.9.2
MOVITRAC
®
B/gateway unit replacement
• Only for device replacement MOVITRAC
®
B with fieldbus option: You have to load
the saved parameter set into the new MOVITRAC
®
B, or you have to perform a com-
plete startup of the inverter (
→
MOVITRAC
®
B operating instructions).
• You have to set the PROFINET IO unit name again using the project planning soft-
ware. Proceed as with an initial startup (
→
section "Project Planning with
PROFINET").
•
Prior to the auto setup
, check the parameters
P884 SBus Baud Rate
and
P831
Fieldbus Timeout response
. The baud rate of the devices connected to the SBus has
to correspond to the baud rate of the gateway (DFE32B). Use the parameter tree of
the gateway in MOVITOOLS
®
MotionStudio.
• Now activate the auto setup function. Set the "AS" DIP switch on the DFE32B option
to 1.
INFORMATION
If you do
not
install the memory card of the replaced MOVIDRIVE
®
B in the new
MOVIDRIVE
®
B, you have to perform a complete startup of the inverter or you have
to load the saved parameter set into the new MOVIDRIVE
®
B. Further, you have to set
the PROFINET IO unit name again using the project planning software. Proceed as
with an initial startup (
→