Chapter D - Setting to work
Rev. A 10-99
DigiDrive Manual Series 2000 / 4000
Pg 43
Servo Dynamics Corp. 21541-D Nordhoff St. Chatsworth, CA 91311 www.servodynamics.com
1.3.5
Axis selector
The axis selector must be on « 0 », the drive replies to RS232 messages sent to address Nr.1.
The axis selector defines the axis number of the drive, from address 1 to 15. The drive will reply
to RS485 messages sent to the corresponding address (Axis selector on 5 -+ drive reply to
messages sent to address Nr. 5).
When the drive does not include the RS485 option (axis selector nonexistent), only the
RS232 link is usable (message constituted with address Nr.1).
See 3.1 Dialogue
protocol
description, page 23, to know the way for the construction of
messages.
The drive must be resetted (send of Reset order or switch Power OFF/ON) to enable a
change of the selector position.
A firmware upgrade is only possible with a RS232 link.
Exception : when drive is programmed with a monitor version 300
h
(or higher), the firmware
update is also possible by RS485 (the parameter 72 indicates the monitor version).
1.4
XMOTOR Connector
Notes :
RS485 link
RS232 link