Modifications and news compared with December 1998 manual :
DESCRIPTION
A 1
5
X
Text adapted for asynchronous motor.
A 3.1
7
X
Storage temperature : « -20 to + 70 »
« -25 to +55 »
A 3.1
7
X
OFF-Trip threshold of overvoltage :
700 VDC
690 VDC
OFF-Trip threshold of undervoltage :
295 VDC
395 VDC
ON-Trip threshold of undervoltage :
280 VDC
380 VDC
A 3.1
7
X
Medium weight added
A 3.1
7
X
« Rated power dissipation during bracking... » line deleted (page 8 table gives the correct
values for all types of drives).
A 3.1
7
X
Incremental encoder simulation : 1 to 1024 (2048)
A 3.2
8
X
Medium electrical and bracking data added
A 3.4
10
X
Medium outlines added.
A 3.3
9-12
X
Mechanical description changed : details added in views and installation plans added.
A 3.8
14
X
Stegmann encoder not more in development.
A 4
15
X
4020 DC BUS fuse type : URGA
URGB.
A 4
15
X
Medium fuses added.
A 0
15
X
New option : AUXILIARY 24V SUPPLY.
A 6
16
X
MKS IR116 and IR117 board added.
Future product : « CAN-BUS interface » deleted.
A 7
17
X
External modules, RS232<->RS485 converter description.
B 0
21
X
Use of 2000WU.exe :
Help can be called only by the menu or by F1 key (icon « ? » removed from toolbar since
version 1.20 of 2000wu).
B 0
21
X
Update firmware with 2000WU.exe procedure :
Change of messages and menus texts (analogy with 2000WU was wrong).
C 0
28
X
P.23, Maximum speed parameter Example : 3200
2960 instead of 3200
2880
C 0
31
X
P.68, Instantaneous motor speed Example : 2667
2467 instead of 2667
2400
D 0
35
X
Note added about PE conductor : PE terminal permanently connected to the earth and
protective conductor cross-section >10mm
2
Cu.
D 0
36
X
DC BUS +/- and DC BUS CTRL terminals are not present when drive is equipped with « EMC
filter » option.
D 0
37
X
XSERIAL 485 indicated as optional
D 0
39
X
Note 2) correction : the inhibit or the free of the movement by end-limit switches, depend of
parameter 24 configuration.
D 0
43
X
When drive is programmed with a monitor version 300
h
(or higher), the firmware update is also
possible by RS485 (the parameter 72 indicates the monitor version)
D 0
50
X
P.23, Maximum speed parameter : conversion error 3000/0.925=3243.2 instead of 3333.3
D 0
53
X
P.15, encoder marker pulse period : more details in description
D 3.2.4 56
X
Detail added : « When P.32 = 0 : Software watchdog disabled »
D 3.3.2 58
X
Current loop equation and gain PID corrections
D 3.3.3 60
X
Speed loop equation correction
L