Pg 26
Servo Dynamics Corp. 21541-D Nordhoff St. Chatsworth, CA 91311 www.servodynamics.com
Chapter C - Drive parameters
Rev. A 10-99
DigiDrive Manual Series 2000 / 4000
C
HAPTER
C
D
RIVE
P
ARAMETERS
The 208 parameters of the drive are divided as follows :
Parameter address
Description
Access
0..5
Motor parameters.
Read/write
Parameters
6..40
Installation parameters.
41..45
Scope parameters.
48..53
Command parameters.
60..63
Internal register (for tests,..).
64..95
Status parameters.
Read only
parameters
100..179
Scope values.
180..207
Diverse parameters
For a few read/write parameters, a change of the value by a write order isn’t directly considered.
An indication is given in the « ST. » column for the read/write parameters :
C
: compute order must be sent to the drive to consider the change of the parameter
(only for SSI)
S
: « Store parameters in FLASH » must be sent to the drive, for it to consider the
change.
Nothing
: the change is directly considered.
Other abbreviations :
R/W
: read/write parameter.
R
: read only parameter.
O
: optional parameter (depend of firmware)
n.i
: parameter not included at this time.
Important :
When VXXX
(i.e. V2005
) is indicated in the table, the function is only avaible with
specified firmware version (i.e. version 2005) or higher version.
1. Parameters description
Содержание DigiDrive 2000 Series
Страница 2: ...www servodynamics com...