Chapter D - Setting to work
Rev. A 10-99
DigiDrive Manual Series 2000 / 4000
Pg 57
Servo Dynamics Corp. 21541-D Nordhoff St. Chatsworth, CA 91311 www.servodynamics.com
S
TATUS DISPLAY
7
SEGMENT VALUE
, A
DDRESS
51
0: Internal status (the display indicates drive alarms or status)
Change this value to force the display of any information (drive alarms are hidden).
bit7 = DP
bit3 = SEGMENT D
bit6 = SEGMENT A bit2 = SEGMENT E
bit5 = SEGMENT B bit1 = SEGMENT F
bit4 = SEGMENT C
bit0 = SEGMENT G
M
OTOR REVOLUTIONS COUNTER
, A
DDRESS
52.
This value can be read for motor position consulting and can be reset at a chosen position.
3.3
Regulation parameters
3.3.1 Configuration
S
PEED OR
C
URRENT LOOP CONTROL
, A
DDRESS
26.
0 for speed loop and 1 for current loop control. When speedloop is chosen, the command is read
as a speed, when currentloop the command is read as a current.
D
IGITAL OR
A
NALOGUE COMMAND
, A
DDRESS
27.
0 for digital and 1 for analogue.
Digital command :
parameter 50 (Digital command) is read to set the command value.
Analogue command :
Input voltage SPEED IN is converted to set the command value.
D
IGITAL COMMAND
(
SPEED OR CURRENT
), A
DDRESS
50.
When digital command mode is set, this parameter defines the command value.
A
NALOGUE COMMAND OFFSET
, A
DDRESS
28.
When analogue command mode is chosen, the input offset voltage can be adjusted with this
parameter.
F
A
B
G
E
C
D
DP