Chapter E - Aynchronous motor
Rev. A 10-99
DigiDrive Manual Series 2000 / 4000
Addr.
St.
R/W
Unit
Limits
Description
9
R/W
100
%
7
FFFh
0..15%
Slip factor
11
R/W
-
0..1
Cosinus phi
54
R/W
1/revolution
0..7FFFh
Encoder input resolution
55
R/W
0.925 RPM
8000h..7FFFh
Field weakening speed
65
R
Alarm register
Bit
Description
Drive Display
10
Overspeed asynchronous
S
LIP FACTOR
, A
DDRESS
9.
Slip factor defined the ratio :
Speed
synchronous
Speed
Speed
synchronous
Standard value=1..7%, usually, 4% is a good value.
C
OSINUS PHI
, A
DDRESS
11.
The cosinus phi is given from the manufacture, usually, a value between 0.8 and 0.9.
2.1
Field weakening
F
IELD WEAKENING SPEED
, A
DDRESS
55.
If field weakening is needed, this parameter must be set to the speed value the field weakening
must begin.
2.2
Asynchronous alarm
Asynchronous overspeed, set when the motor speed is higher than 133% of synchronous
speed (only if field weakening is disabled).
Servo Dynamics Corp. 21541-D Nordhoff St. Chatsworth, CA 91311 www.servodynamics.com