background image

USER MANUAL – Z-TWS4/Z-PASS2-S/S6001-RTU 

 
 

 

 

123 

 

 

 

 

If the GPS signal is not available, the “GPS Location” row contains the string “Not fixed” and the 

Map

 link is 

not shown. 

The following figure shows the situation when an error in PIN setting has occurred, due to a wrong value of 
the PIN parameter. 

Содержание S6001-RTU

Страница 1: ...and effectively read carefully the following instructions before use The product must be used only for the use for which it was designed and built Any other use must be considered with full responsib...

Страница 2: ...R01 25 5 3 Z PASS2 S IO 27 5 4 Z TWS4 IO 28 5 5 S6001 RTU 29 6 Discovering the IP address 30 7 FTP SFTP access 32 8 StratON PLC 33 8 1 Writing downloading and running the first program 33 8 1 1 Senec...

Страница 3: ...uration 100 18 1 8 FW Upgrade 102 18 1 9 Configuration Management 111 18 1 10 Modbus TCP Client Configuration 114 18 1 11 Mobile Network 116 18 1 12 DDNS Configuration 130 18 1 13 Digital I O Configur...

Страница 4: ...15 PUT_ALARM 190 19 1 16 S7_DB_READ 191 19 1 17 S7_DB_WRITE 192 19 1 18 SEND_MAIL 193 19 1 19 SEND_SMS 194 19 1 20 SERVICE_CTRL 195 19 1 21 SET_ALARMS_STAT 196 19 1 22 TIME_SYNC 197 19 1 23 UAC_CONNE...

Страница 5: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 5 21 1 Shared Memory 205 21 2 C program example 206 21 3 CGI 208 21 3 1 CGI readVariable 209 21 3 2 CGI writeVariable 209 22 Glossary 210...

Страница 6: ...ONTENTS OF THIS MANUAL IN ANY TIME WITHOUT NOTICE TO CORRECT EXTEND OR INTEGRATING FUNCTION AND CHARACTERISTICS OF THE PRODUCT ATTENZIONE IN NESSUN CASO SENECA O I SUOI FORNITORI SARANNO RITENUTI RESP...

Страница 7: ...ault values also for User Pages Paragraph Real Time Clock Setup added Central Europe time zone value Paragraph VPN Configuration OpenVPN Client revision into VPN Configuration OpenVPN added packet byt...

Страница 8: ...pplication by a USB pen Chapter Upgrading the firmware added notes about LEDs blinking Paragraph Main View admin updated figure Paragraph Network and Services added info about new Web Server and File...

Страница 9: ...r Technical specifications updated info about modem Removed None value of Security Level Service Disable parameter 15 03 2018 15 Removed CTS signal from COM1 port Z TWS4 Z PASS2 S Added parts related...

Страница 10: ...choose if the two ports shall work in LAN WAN mode or Switch mode by means of a new configuration parameter Ethernet Mode there are 4 more LEDs providing information about the Ethernet Mode and the VP...

Страница 11: ...s minimum 110 bps COM 1 removable 4 pin connector as an alternative to RS485 CAN CAN bus port 2 0A and 2 0B Baud rate maximum 500 Kbps minimum 20 Kbps screw terminals 10 11 12 or IDC10 connector avail...

Страница 12: ...RTU Microprocessor 8 bits 24 MHz 3G MODEM Z PASS2 S S6001 RTU HSPA Modem 14 4 Mbps in downlink 5 76 Mbps in uplink Slot for SIM card Mini SIM with push push connector 3G MODEM Z PASS2 S IO Speed HSPA...

Страница 13: ...GU Korea IC Rogers Canada Anatel Brazil CCC SRRC NAL China Under Development Slot for mini SIM Mini SIM with push push connector POWER SUPPLY Z TWS4 Z PASS2 S Power supply 11 40 Vdc or 19 28 Vac 50 60...

Страница 14: ...onnectors for Main and Diversity antennas BOX DIMENSIONS Z TWS4 Z PASS2 S Dimensions Z TWS4 L 100 mm H 112 mm W 35 mm Z PASS2 S L 100 mm H 112 mm W 53 mm Case Nylon 6 with 30 fiberglass field self ext...

Страница 15: ...tion 3 kV Liquid level control inputs conductive liquid level switch 2 channels adjustable sensitivity The following table shows which frequency bands are supported by the modem available in Z PASS2 S...

Страница 16: ...ugh 14 15 screw terminals If Z PC DINAL1 35 or Z PC DINAL2 52 5 17 accessory is used the power supply signals and communication signals may be provided by the terminals block into the DIN rail support...

Страница 17: ...d RS485 port In order to select the RS232 port on the removable 4 pin connector put the SW2 DIP switch on ON position to select the RS485 port on the removable 4 pin connector put the SW2 DIP switch o...

Страница 18: ...ple or to connect an external USB memory this is used for FW upgrade see chapter 17 Please note that on this USB port the hotplug feature is not available so after plugging the USB device it is necess...

Страница 19: ...for micro SD card placed in the side part of the case To insert the SD card into the connector be sure that the SD card is oriented with metal contacts facing towards left with reference to the figur...

Страница 20: ...for the Digital Inputs shall be arranged as in the following figures The electrical connections for the Digital Outputs shall be arranged as in the following figure 4 1 2 Z PASS2 S IO Digital I Os In...

Страница 21: ...rminals 52 and 53 The supply voltage must be 24 15 Vac dc any polarity Upper limits must not be exceeded to avoid serious damage to the device It is necessary to protect the power supply source agains...

Страница 22: ...ar to send In 9 RI Ring indicator In An optional communication bus is available on removable screw terminals 60 61 62 for future extensions S6001 RTU has 1 USB port which is an USB HOST with connector...

Страница 23: ...or 1 analog current output 0 20 mA Available between 47 and 50 screw terminals 1 analog voltage output 0 10 Vdc Available between 48 and 50 screw terminals The Liquid Level Inputs are available on scr...

Страница 24: ...minals 71 94 as shown in the following figure Eight SPDT relays are available to control for example external pumps The operating voltage is 250 Vdc 2 A The 15 digital inputs are available on screw te...

Страница 25: ...ta activity Ethernet 2 There is no data activity Ethernet 2 RX1 2 4 Red Blinking ON OFF Data reception COM 1 2 4 Check the connection COM 1 2 4 No data reception COM 1 2 4 TX1 2 4 Red Blinking ON OFF...

Страница 26: ...connection is not working properly VPN Box functionality is disabled RX1 2 4 Red Blinking ON OFF Data reception COM 1 2 4 Check the connection COM 1 2 4 No data reception COM 1 2 4 TX1 2 4 Red Blinkin...

Страница 27: ...abled Remote Connection is enabled VPN Green ON Blinking OFF VPN connection is working properly VPN connection is not working properly VPN functionality is disabled or VPN Box Point to Point functiona...

Страница 28: ...There is data activity Ethernet 1 2 There is no data activity Ethernet 1 2 5 4 Z TWS4 IO LED Status Meaning PWR Green ON The module is powered on RUN Green Blinking The module is ready for use DIDO G...

Страница 29: ...transmission COM 2 4 Check the connection COM 2 4 No data transmission COM 2 4 Ethernet Connector LEDS LED Status Meaning ETH1 2 Green ON OFF Ethernet 1 2 connection detected Ethernet 1 2 connection a...

Страница 30: ...WR SIG LED 1 is blinking synchronously with RUN LED in the following situations o GSM 3G network is not available or signal level is too low o SIM is not inserted Modem LEDS LED Status Meaning 3G PWR...

Страница 31: ...U device and other Seneca products found in the LAN Moreover by clicking on the Assign button it is possible to change the network configuration parameters of a device as shown in the following figure...

Страница 32: ...e LAN IP Address when the PC is connected to the LAN port the WAN IP Address when the PC is connected to the WAN port moreover the network configuration parameter changes apply to the relevant port 7...

Страница 33: ...itor and program editors compliant with the five languages of the IEC 61131 3 Standard Sequential Function Chart SFC Function Block Diagram FBD Ladder Diagram LD Structured Text ST Instruction List IL...

Страница 34: ...e used to install the StratON IDE and Z NET4 SW see chapter 20 The installer is available at the following link http www seneca it products seneca straton package If for some reasons the installer can...

Страница 35: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 35 Then import the Library menu Tools Import...

Страница 36: ...ocedure to add the Profiles library to the IDE is identical to the one just explained the only difference is that the SenecaStratonProfiles XL5 file shall be selected instead of the SenecaStratonLibra...

Страница 37: ...owing folders TWS_MISC ZPASS2_Template S6001_Template The TWS_MISC folder shall be copied into the following directory C Users Public Documents Copalp STRATON LIBS The ZPASS2_Template and S6001_Templa...

Страница 38: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 38 8 1 2 Creating a project for Seneca CPUs Run the StratON IDE and create a new project based on a template as in the following figure...

Страница 39: ...39 Select the ZPASS2_Template or S6001_Template in the template list Now as you can see in the following figure in the Main program a ZMODEM_MNG UDFB instance is already available which lets you easil...

Страница 40: ...Z TWS4 Z PASS2 S S6001 RTU 40 Set the correct target IP address for example 192 168 85 106 normally the port shall be set to 502 Then press the icon to compile the project Download the code by pressi...

Страница 41: ...of the Device If the Straton project is not based on ZPASS2_Template S6001_Template the Seneca UDFB library can still be used as described in the following In the Straton IDE go to the Project Settin...

Страница 42: ...nd click on Add Finally click on Close Now the UDFB library is available in the project as shown in the following figure If the Straton project has been built using the Seneca Z NET4 SW see chapter 20...

Страница 43: ...traton IDE and related tools please refer to StratON tutorials and on line help 8 1 3 Z PASS2 S IO profiles Two Straton I O profiles are available for Z PASS2 S IO CPU The first profile named ZPASS_DI...

Страница 44: ...l outputs The second profile named ZPASS_GPS provides variables corresponding to the information given by the GPS module as shown in the following figure In particular the GPS_ERROR variable tells if...

Страница 45: ...ement protocols IEC 60870 5 101 Master Slave IEC 60870 5 104 Master Slave IEC 61850 Master Slave The activation of these protocols is license based Please contact Seneca to get more information about...

Страница 46: ...as shown in the following figures Please see paragraph 18 1 2 for a description of the configuration parameters related to StratON Redundancy 9 Ethernet Mode Z PASS2 S R01 Z PASS2 S IO Z TWS4 IO In Z...

Страница 47: ...from the enterprise network connected to the WAN interface comprising enterprise PCs and servers when the Device is remotely accessed through the WAN interface only devices connected to the LAN interf...

Страница 48: ...t come from using a VPN are secure connections since transported data are encrypted the ability to establish connections without interfering with the corporate LAN no need to have a static public IP a...

Страница 49: ...VPN BOX Manager configures VPN BOX and will help you to avoid errors defining local subnets In the Point to Point VPN a client PC in a given moment can perform a single connection on demand to only o...

Страница 50: ...wing two sub paragraphs give some more info about the two kinds of VPN 10 1 Single LAN VPN The above figure gives an example of a Single LAN VPN The client PC with IP address 192 168 1 X can connect j...

Страница 51: ...voided using a Single LAN VPN is still possible if local IP addresses are not used devices can be reached by means of their VPN IP addresses and machines beyond them can be reached by configuring some...

Страница 52: ...when a 3G modem is available true for Z PASS2 S and S6001 RTU This functionality switches the network interface used to access the Internet from the Ethernet primary interface to the Mobile 3G second...

Страница 53: ...ddress of the WAN Mobile Network interface Another important feature is the availability of a DNS server forwarder which can resolve names either by itself or querying the external configured DNS serv...

Страница 54: ...but the device can still access the Internet and send receive SMSs Level 3 Internet Connection any Internet access is disabled but the device can still send receive SMSs Level 4 SMS Service modem is o...

Страница 55: ...PC UA is a standardized machine to machine communication protocol for industrial 4 0 automation developed by the OPC Foundation OPC UA is a vendor independent communication protocol and it s based on...

Страница 56: ...s explained in the following paragraphs Furthermore for S6001 RTU one more page I O View is available 18 1 Administrator pages The Device can be fully configured by means of a set of web configuration...

Страница 57: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 57 18 1 1 Main View In this page main Device configuration parameters are shown with their current values...

Страница 58: ...if the PLC application execution is stopped or no application is loaded on the Device the status app not running is also shown if the PLC application is running the name of the application is also sho...

Страница 59: ...ANUAL Z TWS4 Z PASS2 S S6001 RTU 59 The previous figure shows the Network and Services page for a Z PASS2 S IO when the Ethernet Mode parameter is set to Switch it also applies to a Z TWS4 IO in Switc...

Страница 60: ...NUAL Z TWS4 Z PASS2 S S6001 RTU 60 The previous figure shows the Network and Services page for a Z PASS2 S IO when the Ethernet Mode parameter is set to LAN WAN it also applies to a Z TWS4 IO in LAN W...

Страница 61: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 61 The previous figure shows the Network and Services page for a Z PASS2 S R01 when the Ethernet Mode parameter is set to Switch...

Страница 62: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 62 The previous figure shows the Network and Services page for a Z PASS2 S R01 when the Ethernet Mode parameter is set to LAN WAN...

Страница 63: ...k and Services page for a S6001 RTU it also applies to a Z TWS4 and Z PASS2 S old version There is an important difference between the parameter values shown in this page and those shown in the Main V...

Страница 64: ...shown or renamed as described below This parameter is available only for Z PASS2 S R01 Z PASS2 S IO and Z TWS4 IO products For all other products only Switch mode is available hence the parameter is n...

Страница 65: ...Static or dinamically assigned by the DHCP Server value DHCP DHCP for Z TWS4 R0x and Z PASS2 S R0x x 1 2 Static for all other products NETWORK DNS Server DNS server IP address disabled when DHCP func...

Страница 66: ...Redundancy Enable Flag to enable disable the Straton Redundancy functionality OFF PLC Straton Redundancy IP Address IP address of the second Device used for Straton Redundancy 192 168 90 102 PLC Lice...

Страница 67: ...e notes about the DHCP parameters the DHCP parameter can be set to ON only if the DHCP Server parameter of the Router Configuration page is set to OFF see paragraph 18 1 5 only the DHCP on WAN paramet...

Страница 68: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 68...

Страница 69: ...a login may be needed to access the shared folder if so use the credentials shown in the following figure username guest password empty 18 1 3 Real Time Clock Setup By clicking on the Real Time Clock...

Страница 70: ...WS4 Z PASS2 S S6001 RTU 70 This page is made up of two sections NTP and RTC In the NTP section you can change the parameters related to the Network Time Protocol and to the Time Zone as listed in the...

Страница 71: ...im it NTP Secondary Server IP address or FQDN of the Secondary NTP Server ntp2 inrim it NTP Time Zone Time Zone Central Europe CET CEST When the Time Zone parameter is set to Central Europe CET CEST v...

Страница 72: ...if NTP time synchronization is not enabled when NTP Enable parameter is ON the input fields and the SET CLOCK button are disabled and the parameters are only for viewing Instead when NTP Enable param...

Страница 73: ...the General Configuration menu you come to the following page The page has a different layout depending on the value of the VPN Mode parameter which can be OpenVPN or VPN Box for an explanation of th...

Страница 74: ...described in the following 18 1 4 1 1 Configuration File This file shall contain all the information needed to configure the Open VPN behaviour the main configuration options are13 if the Device shal...

Страница 75: ...hat logs are written to syslog An example of a client configuration file is given in paragraph 18 1 4 1 7 18 1 4 1 2 CA certificate This file shall contain the Certification Authority CA certificate a...

Страница 76: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 76...

Страница 77: ...on the SHOW VPN STATUS button as shown in the following figure remember that the configuration file is renamed as ovpn conf As reminded by the web page the VPN files can be downloaded from the Device...

Страница 78: ...requiring a confirmation If VPN is enabled the user is not allowed to delete VPN files as warned by the following pop up In the VPN Configuration section there is only one parameter as described in t...

Страница 79: ...y told above if you try to enable the VPN connectivity but no configuration file has been uploaded to the Device yet an error is given as shown in the following figure When you click on the SHOW VPN S...

Страница 80: ...n Disconnected the OpenVPN Status i e Stopped or Running the number of packets bytes received from the VPN interface when connected 0 0 when disconnected the number of packets bytes sent to the VPN in...

Страница 81: ...tatus is Stopped Open VPN process could not be correctly started probably the configuration file contains some errors or maybe some options not supported by the Device Open VPN implementation You can...

Страница 82: ...1 7 OpenVPN Client configuration file This paragraph gives an example of OpenVPN client configuration this is the client configuration typically loaded on Z TWS4 Z PASS2 S S6001 RTU devices client de...

Страница 83: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 83 OFF VPN functionality is disabled SERV Green Not used 18 1 4 2 VPN Box The page contains only ony section VPN Box as shown in the following figure...

Страница 84: ...Z PASS2 S S6001 RTU 84 The VPN Box section contains the following parameters Field Meaning Default value VPN BOX Enable Flag to enable disable the VPN Box functionality that is the procedure protocol...

Страница 85: ...tatus showing the VPN Connection Status i e Disconnected or Connected the IP address assigned to the VPN interface when Connected the dummy IP address 0 0 0 0 when Disconnected this row is not shown f...

Страница 86: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 86...

Страница 87: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 87...

Страница 88: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 88 For an explanation of the differences between a Single LAN VPN and a Point to Point VPN see chapter 10 The VPN Box Status string has the following format...

Страница 89: ...t configured yet Single LAN only OK Configuration updated The Device configuration has just been updated OK Configured The Device is properly configured and available for VPN connection OK Ban The Dev...

Страница 90: ...lity is enabled in VPN Box Point to Point mode the SERV and VPN LEDs give the following status information see chapter 5 LED Status Meaning VPN Yellow ON OFF A VPN client is connected to the Device No...

Страница 91: ...have a set of general parameters as listed in the following table Field Meaning Default value Router Enable Flag to enable disable the Router functionality OFF Ethernet Bandwidth Limitation This param...

Страница 92: ...Last Address These parameters define the range of IP addresses assigned by the DHCP server to requesting clients 192 168 90 201 192 168 90 210 DHCP Lease Time min Validity period for the IP address a...

Страница 93: ...l be set to ON to protect the Device against undesired maybe malicious accesses This is the only parameter in the Router Configuration page that is working also when the Router functionality is disabl...

Страница 94: ...ping rules also known as Virtual Servers in each section the available parameters are the following Field Meaning Default value Protocol This parameter defines the transport protocol or kind of port w...

Страница 95: ...nternal Port TCP or UDP port which the received packet is forwarded to Empty If Router is left disabled Router Enabled OFF you can still change parameters changes will be saved without actually applyi...

Страница 96: ...DHCP server functionality DHCP Server Enable ON but the DHCP First Address and DHCP Last Address parameters define an address range that is not congruent with the Ethernet configuration IP address an...

Страница 97: ...ER MANUAL Z TWS4 Z PASS2 S S6001 RTU 97 As already told before the Router configuration page lets you define up to 5 Port Forwarding rules or Virtual Servers An example is given in the following figur...

Страница 98: ...however by doing this the access to the custom user s pages won t be possible anymore the second rule tells the Device that any TCP or UDP packet received on the 502 port which is often used for Modb...

Страница 99: ...ublic IP address assigned to the 3G interface the 8080 and 22 TCP ports shall be open this can be done as shown in the following figure 18 1 6 OPC UA Server Configuration By clicking on the OPC UA Ser...

Страница 100: ...ubscription empty Password The password provided with the service subscription empty Shared Memory Select which shared memory must access with the OPC UA protocol Z NET Note that for access the server...

Страница 101: ...this page you can change the Web Administrator Web User Web Guest and FTP User credentials as explained in the following table Field Meaning Default value WEB ADMINISTRATOR Username Username to access...

Страница 102: ...Username to access the Device FTP SFTP site see chapter 7 user FTP USER Password Password to access the Device FTP SFTP site see chapter 7 123456 For all the fields in this page the following characte...

Страница 103: ...the FW upgrade the RESTART TWS SERVICES button lets you restart the TWS services which otherwise would remain in the stopped state Otherwise if you click on the Cancel button of the pop up TWS Service...

Страница 104: ...to the user to choose if Soft PLC shall be stopped or not during FW Upload on one side stopping it is more safe and let the upload be completed in a shorter time on the other side there are situation...

Страница 105: ...provided by Seneca with the support of Seneca personnel This page lets you browse your PC to select the file containing the FW which shall have a name of the following type SW002940_xxx bin14 If you...

Страница 106: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 106 Once a file is selected you can start the upload by pressing the UPLOAD button...

Страница 107: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 107 Once the upload is successfully completed the following page is shown...

Страница 108: ...PASS2 S S6001 RTU 108 In this page you can press the Upgrade and Reboot button this will start the upgrade procedure which takes some minutes to be completed during this time the Device MUST NOT be sw...

Страница 109: ...ade procedure is ended when only the LED RUN is blinking16 15 This applies only to products with HW revisions IO and R01 in details for IO HW revision all LEDs will blink simultaneously except for Pow...

Страница 110: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 110 press the Cancel and Reboot button this will delete the uploaded file on the Device and perform the reboot...

Страница 111: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 111 18 1 9 Configuration Management By clicking on the Conf Management link in the General Configuration menu you come to the following page...

Страница 112: ...USB pen is the following copy the SW002940_conf tar gz or SW002940_conf zip see below file into the root folder of the USB pen switch off the Device insert the USB pen into the USB 1 port of the Devic...

Страница 113: ...note that to get detailed debug logs the DEBUG LOGS Enable parameter in Network and Services page shall be set to ON 18 1 9 1 Factory reset by USB pen A USB pen can be used also to reset the Device to...

Страница 114: ...the procedure will take some minutes to be completed during this time the Device MUST NOT be switched off during the procedure the Device will be rebooted after the reboot wait until you see the RUN L...

Страница 115: ...001 RTU 115 This page lets you change the IP Address and TCP Port of the Modbus TCP Client Open MODBUS in the Fieldbus Configurations of the Straton project the change can be done without the need of...

Страница 116: ...nfiguration web page In the following table all configuration parameters available in the page are listed with a short explanation and the parameter default value for each of them Field Meaning Defaul...

Страница 117: ...117 The above figure shows the Mobile Network page for Z PASS2 S IO For Z PASS2 S R01 Z PASS2 S and S6001 RTU the Operator Selection section and the GET OPERATOR LIST button are not available so the p...

Страница 118: ...8 In this page you can change the parameters related to the Mobile Network as listed in the following table Field Meaning Default value SIM PIN if required by SIM PIN needed to unlock the SIM card if...

Страница 119: ...PERATOR LIST button 22201 I TIM UMTS Data Connection Enable Flag to enable disable the Mobile Network connectivity OFF Data Connection APN Mode This parameter tells if the APN and related parameters a...

Страница 120: ...n the SHOW MOBILE STATUS button a new section appears named Mobile Status showing the SIM PIN Status if an error in PIN setting has occurred or PUK PUK2 setting is needed this status is shown in red c...

Страница 121: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 121...

Страница 122: ...S6001 RTU 122 As shown in the above figures only for Z PASS2 S IO the last row of the Mobile Status gives the GPS Location as Latitude Longitude values clicking on the Map link the Google Maps on the...

Страница 123: ...If the GPS signal is not available the GPS Location row contains the string Not fixed and the Map link is not shown The following figure shows the situation when an error in PIN setting has occurred...

Страница 124: ...ed that when the PIN is set during procedures automatically performed by the Device firmware if the number of remaining attempts is 1 no more attempt is done to avoid blocking the SIM You can refresh...

Страница 125: ...ection by clicking on the HIDE MOBILE STATUS button As already told above the GET OPERATOR LIST button lets you retrieve the list of the operators currently available that is detected by the modem onl...

Страница 126: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 126 Tipically it takes about 1 minute to get the list so the page shows the number of seconds elapsed...

Страница 127: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 127 When the procedure is completed the following page is shown...

Страница 128: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 128 After some seconds the page automatically evolves to the Mobile Network page with the operator list filled as shown in the following figure...

Страница 129: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 129 You can choose an operator from the list to perform Manual or Manual Automatic selection...

Страница 130: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 130 18 1 12 DDNS Configuration By clicking on the DDNS Configuration link in the Mobile Configuration menu you come to the following page...

Страница 131: ...namic DNS service possible values are None dyndns it dyndns org no ip com None Hostname The hostname provided with the service subscription empty Username The username provided with the service subscr...

Страница 132: ...ER MANUAL Z TWS4 Z PASS2 S S6001 RTU 132 When an IP address assigned to the Mobile Network Interface has been bound with the hostname the DDNS Update Status section appears like in the following figur...

Страница 133: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 133...

Страница 134: ...licking on the Digital I O Configuration link in the Digital I O menu you come to the page described in the following sub paragraphs19 the page differs between Z TWS4 IO and Z PASS2 S IO 18 1 13 1 Z P...

Страница 135: ...s page you can configure the operating modes of the Digital I Os and the security level applied by the Remote Connection Disable feature see chapter 13 Field Meaning Default value Input 1 Mode This pa...

Страница 136: ...represents the operating mode of the Digital Output 2 DO 2 Possible modes are General output Remote toggle 20 General output Input Output 1 Mode This parameter represents the operating mode of the Di...

Страница 137: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 137 description of these values The Digital I O Status section of the page gives the current status values LOW HIGH for each of the six available digital I Os...

Страница 138: ...WS4 Z PASS2 S S6001 RTU 138 The status of the digital input configured as Local Alarm is reported in the ALARM column in the Devices tab of the Seneca VPN Box Manager and Seneca VPN Client Communicato...

Страница 139: ...an configure the operating modes of the Digital I Os and the security level applied by the Remote Connection Disable feature see chapter 13 Field Meaning Default value Output 1 Mode This parameter rep...

Страница 140: ...ter represents the operating mode of the Digital Input Output 2 second configurable digital I O DIDO 2 Possible modes are General input General output Local alarm General output Service Disable This p...

Страница 141: ...ut 1 Input 15 Status of Digital Input LOW HIGH DIGITAL OUTPUTS Output 1 Output 8 Status of Digital Output relay OPEN CLOSED DIGITAL OUTPUTS 12 Volt Enable Output Status of Digital Output enabling 12 V...

Страница 142: ...his parameter gives an information about errors that might occur in the I O board The value is a bitmask as specified in the column Values 0 no error Bit 9 flash memory error DIAGNOSTICS CRC Error Cou...

Страница 143: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 143 18 1 15 FW Versions By clicking on the FW Versions link in the Diagnostics menu you come to the following page...

Страница 144: ...SS2 S S6001 RTU 144 In this page the following information are shown the product name along with its HW revision in the above figure Z PASS2 S R01 the version strings of all the FW components which ar...

Страница 145: ...s o Default Disk File System diskdfl o Disk File System disk 18 1 16 Ethernet Interfaces By clicking on the Ethernet Interfaces link in the Diagnostics menu you come to the following page The above fi...

Страница 146: ...mber of packets bytes received from the Ethernet interface when the link is up 0 0 when the link is down the number of packets bytes sent to the Ethernet interface when the link is up 0 0 when the lin...

Страница 147: ...umber of packets bytes received from the Ethernet interface the number of packets bytes sent to the Ethernet interface You can refresh the Ethernet status by clicking on the REFRESH button 18 1 17 Mod...

Страница 148: ...module the module status which can be o OK if the module is correctly responding to Modbus requests o TIMEOUT if the module is not responding to Modbus requests o ERROR if any other error occurs The...

Страница 149: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 149 18 1 18 M Bus Scan By clicking on the M Bus Scan link in the M Bus menu you come to the following page...

Страница 150: ...see paragraph 18 1 2 The SECONDARY SCAN button lets you scan the bus detecting M Bus secondary addresses select the correct baud rate for the COM1 serial port or select All to repeat the scan for any...

Страница 151: ...number of seconds elapsed the devices are shown in term of their secondary address and baud rate as soon as they are detected The STOP SCAN button lets you abort the procedure anyway the partial resu...

Страница 152: ...set FACTORY DEFAULT button in Main View page In the same way the PRIMARY SCAN button lets you scan the bus detecting M Bus primary addresses select the correct baud rate for the COM1 serial port or se...

Страница 153: ...ond table contains a variable number of rows each providing a data record By clicking on the REFRESH button you can refresh the data by clicking on the BACK button you come back to the page with the d...

Страница 154: ...ed the actual M BUS configuration The webserver than move automatically to the next M Bus Configuration page 18 1 19 M Bus Configuration When you have pressed the Create Configuration in the M Bus Sca...

Страница 155: ...e Straton Tag Prefix name for the device The 2nd column represent the Baud Rate to use The 3rd column represent the Device Address The 4th column represent the Scan Rate in seconds for this device 18...

Страница 156: ...s automatic acquisition process will start At the end of the process a zip file mbus_tags zip will be downloaded The zip contain 4 files Two of these files must be used in Straton mbus_shm csv the sha...

Страница 157: ...SER MANUAL Z TWS4 Z PASS2 S S6001 RTU 157 Extract the zip file in a directory Now launch Straton PLC Select Main then Global Variables Now click the right mouse button and select Edit Variables as Tex...

Страница 158: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 158 Select the mbus_vars csv file and click save The variables are imported...

Страница 159: ...R MANUAL Z TWS4 Z PASS2 S S6001 RTU 159 Now we must create the shared memory used for sharing the data from M BUS Click on fieldbus icon Click with the right mouse button and select Insert Configurati...

Страница 160: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 160 Now create the Embedded Shared Memory Insert a Master Port...

Страница 161: ...MANUAL Z TWS4 Z PASS2 S S6001 RTU 161 The Shared configuration MUST be don t change any setting Now insert the data Block Create a name group use the name that you want Then import the shared memory...

Страница 162: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 162 Select the mbus_shm csv file...

Страница 163: ...offsets of others variables are not changed 18 1 19 3 Replace a M BUS Device For Replace an existing M BUS device for example in case of a replace for failure 1 Go to M BUS Scan and make a Secondary o...

Страница 164: ...ce 1 Go to M BUS Scan and make a Secondary or Primary Scan 2 Take note of the Device address to delete 3 Go to M BUS Configuration and manually delete the device with the DELETE button 4 Push the Crea...

Страница 165: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 165...

Страница 166: ...nctions see chapter 20 The page lets you perform the following operations browse the SD folder tree clicking on the folder name links delete a folder clicking on the delete link create a new folder by...

Страница 167: ...dragging it into the dashed area the file is created in the folder currently shown clean the SD by means of the Clean SD button please note that this is done by formatting the SD so all SD contents w...

Страница 168: ...page is also available Also the FW Versions Ethernet Interfaces and Modbus Modules pages of the Diagnostics section are available for this kind of user they will not be shown again here as they are i...

Страница 169: ...169 18 2 1 Main View In this page some Network parameters and the Web User credentials are shown with their current values To change the parameter values you have to go to the Network and Services pag...

Страница 170: ...and Services The parameters shown in this page slightly change depending on the HW version of the product Z TWS4 Z PASS2 S or Z PASS2 S R01 Z PASS2 S IO Z TWS4 IO and for new HW versions on the selec...

Страница 171: ...1 RTU 171 The previous figure shows the Network and Services page for a Z PASS2 S R01 Z PASS2 S IO Z TWS4 IO when the Ethernet Mode parameter is set to Switch it also applies to a Z TWS4 and Z PASS2 S...

Страница 172: ...n in user pages Field Meaning Default value Ethernet Mode Switch NETWORK DHCP Flag to enable disable the DHCP functionality on the Ethernet interface OFF NETWORK IP Address IP address of the Ethernet...

Страница 173: ...ll other products NETWORK DNS Server DNS server IP address disabled when DHCP functionality is enabled on any interface and DNS Mode DHCP 192 168 100 1 for Z TWS4 R0x and Z PASS2 S R0x x 1 2 192 168 9...

Страница 174: ...he pages except for FW Upgrade Configuration Management and Data Logs pages viewing all configuration parameters and status information without changing any parameter so in all the pages the APPLY but...

Страница 175: ...USER MANUAL Z TWS4 Z PASS2 S S6001 RTU 175 and when asked provide the following credentials default values Username guest Password guest You come to the Main View page shown in the following figure...

Страница 176: ...WS4 Z PASS2 S S6001 RTU 176 Note that as told above the FACTORY DEFAULT RESTART and CLEAN INTERNAL DATA LOGS buttons are disabled Another example of a page accessed by the guest user is given in the f...

Страница 177: ...TUS HIDE MOBILE STATUS and REFRESH buttons are enabled letting the guest user to view the Mobile Status 19 Seneca StratON Library To let the users exploit Z TWS4 Z PASS2 S S6001 RTU features in their...

Страница 178: ...the parameter value during the FB execution when the execution is completed the FB code itself will put ENABLE FALSE output when the FB is called with ENABLE FALSE it does nothing and returns the NOT_...

Страница 179: ...hen first called the FB runs a process which starts performing the upload on subsequent calls it only checks if the process has finished its job The FB has the following input parameters HOST IP addre...

Страница 180: ...es possible values MAX_REC the maximum number of records lines to be retrieved FILENAME the file name with absolute path ENABLE TRUE FB is executed FALSE FB is skipped the parameter is set to FALSE by...

Страница 181: ...UT timeout in seconds ENABLE TRUE FB is executed FALSE FB is skipped The FB has the following output parameters RESULT 2 when called with ENABLE FALSE 1 in case of any failure 0 if the process is stil...

Страница 182: ...txt create the directory list into output1 txt 19 1 7 LINUX_SH_ASYNC The LINUX_SH_ASYNC FB executes a command in a Linux shell in asynchronous mode When first called the FB runs a Linux shell process...

Страница 183: ...the serial port possible values are 300 600 1200 2400 4800 9600 19200 38400 ADDR M Bus primary 255 or secondary address SEND_INIT flag to enable disable the sending of the SND_NKE reset frame at the...

Страница 184: ...CI_FIELD 51 hex DATA 01 7A 08 hex DATA_LEN 3 19 1 9 MODEM_CTRL The MODEM_CTRL FB sends a generic AT command to the GSM modem and receives the corresponding response When first called the FB runs a pro...

Страница 185: ...if the whole response is longer than 255 characters it will be truncated Please note that the MODEM_CTRL FB can t be successfully executed while the PPP connection is active on Z MINIRTU This FB canno...

Страница 186: ...be sent WAIT wait duration in seconds after sending the command valid values are 30 300 ENABLE TRUE FB is executed FALSE FB is skipped The FB has the following output parameter RESULT 2 when called wi...

Страница 187: ...equired for authentication it can be empty if authentication is not required not used with Automatic APN functionality PASSWORD password required for authentication it can be empty if authentication i...

Страница 188: ...tring GPRS_APN GPRS Access Point Name as given by the mobile network operator if this parameter is left empty Automatic APN functionality is activated USERNAME username required for authentication it...

Страница 189: ...imeout has expired 5 if MODEM_RESET FB is running LOCAL_IP IP address assigned to the PPP network interface only if RESULT 1 when CONNECT TRUE REMOTE_IP IP address of the remote host set as default ga...

Страница 190: ...epresenting the alarm event level e g INFO max_len 10 possible values are defined by the application SOURCE a string representing the alarm event source e g GRP1 max_len 10 possible values are defined...

Страница 191: ...HM_SIZE size of the Straton shared memory which the data are written to DB_NUM the number of the Data Block to be read OFFSET start offset for the read operation in the Data Block LEN number of bytes...

Страница 192: ...SHM_SIZE size of the Straton shared memory which the data are read from DB_NUM the number of the Data Block to be written OFFSET start offset for the write operation in the Data Block LEN number of by...

Страница 193: ...shall be used FALSE SMTP TRUE SMTPS CRYPTO_ON TRUE is available only for Z TWS4 Z PASS2 S AUTH_ON if authentication shall be executed AUTH_USERNAME username for authentication AUTH_PASSWORD password...

Страница 194: ...M SMS Service Center as given by the mobile operator it can be empty if the SC number is already set on the modem SIM TO_NUM recipient number SMS_BODY SMS text TIMEOUT timeout in seconds ENABLE TRUE F...

Страница 195: ...tion 4 SMS Service 1 the value of the Security Level Service Disable configuration parameter will be used TIMEOUT timeout in seconds ENABLE TRUE FB is executed FALSE FB is skipped The FB has the follo...

Страница 196: ...ll be set as alarms stat alarms stat STATUS where alarms stat DB field STATUS this parameter FIRST_ID the id of the first record retrieved by the GET_ALARMS FB LAST_ID the id of the last record retrie...

Страница 197: ...b The FB has the following input parameter ENABLE TRUE FB is executed FALSE FB is skipped The FB has the following output parameter RESULT 2 when called with ENABLE FALSE 1 in case of any failure 0 if...

Страница 198: ...finished CONN_ID connection identifier to be used in UAC_READ UAC_WRITE and UAC_DISCONNECT FB 19 1 24 UAC_DISCONNECT This Function Block can be used to disconnect from an OPC UA Server When first call...

Страница 199: ...B is skipped The FB has the following output parameters RESULT 2 when called with ENABLE FALSE 1 in case of any failure 0 if the process is still running 1 if the process has successfully finished 19...

Страница 200: ...N Box 0 OK 3 Wrong password 7 License limit reached 201 Generic error 202 VPN Box not configured 1000 No transaction has been performed e g VPN Box functionality is disabled other Unexpected response...

Страница 201: ...ile already open IN string to write into the file Output parameters OK boolean result value TRUE success FALSE failure 19 2 2 TXBAPPENDFILE Append a Text Buffer to a file without reloading the file In...

Страница 202: ...DATETIME shall have the following format dd mt yyyy hh mm ss 19 2 4 MBUS_READ_CTL The MBUS_READ_CTL function can be used to enable disable the M Bus read operations It should be noticed that M Bus re...

Страница 203: ...lue see below INPUTS none OUTPUTS RESULT the function result possible values are 0 OK 1 watchdog setting failed WDOG_SET_TMO function has not been called or failed 2 watchdog controlled by system WATC...

Страница 204: ...powerful tool is provided by the Z NET4 program suite running on Windows PCs Among other things these programs let you automatically discover the I O modules available on the bus configure the CPU Z...

Страница 205: ...typically invoked by the lighttpd web server while the second does not require any changes in the Device FW provided that the currently supported CGIs are used 21 1 Shared Memory Straton Workbench let...

Страница 206: ...t_dummy VarREAL 12 4 2 2 CPU_ErrorReport_dummy 21 2 C program example In this paragraph an example is given of a simple C program which can be used to access a shared memory The program arguments lets...

Страница 207: ...eturn 0 ftruncate shmid wSize pMap mmap NULL wSize PROT_READ PROT_WRITE MAP_SHARED shmid 0 if pMap MAP_FAILED printf Error mmap s size d n szName wSize return 0 sem sem_open szName O_RDWR S_IRUSR S_IW...

Страница 208: ...fine VAR_MAX_NUM 100 typedef enum VAR_FORMAT_INT VAR_FORMAT_UINT VAR_FORMAT_FLOAT VAR_FORMAT_STRING VAR_FORMAT_NUM VAR_FORMAT_T const char var_format_str integer unsigned integer float string typedef...

Страница 209: ...ames and possibly the variables modes to tell which variables can be read written and which can only be read 21 3 1 CGI readVariable To read one variable request goform readVariable nVars 1 var1 var_n...

Страница 210: ...between a LAN and a WAN the Internet Switch a networking device that connects devices together on a computer network by using a form of packet switching to forward data to the destination device VPN...

Отзывы: