15.
Connect feeder cable to the Venetian Blind and check
the correctness of system functioning and setting end
positions. If necessary correct according to the motor
manual.
NOTE:
Connection of the feeder cable should be placed
in the marked spot in the cassette in a manner enabling
maintenance. Cable should be placed in such a way so
that no water gets to the motor.
Fig. 16
16.
Install the revision lid to the under-plaster cassette
and secure it with screws as shown on imgs. 18 and
19.
Img. 18
Img. 19
4.6.
ELECTRIC DRIVE
4.6.1.
CONNECTION TO POWER SUPPLY
After the product is installed one may proceed to connecting the drive and control system to the previously prepared
systems: power supply and control systems. Connection to the power supply system should be made in accordance with
the previously elaborated individual electric diagram, including fire protection regulations. The connection must be
performed by an electrician holding appropriate permissions.
Electrical connection and setup of the motors must be done in accordance with the manual of motor manufacturer.
Manuals are added to the product as well as are available on motor manufacturer’s website and:
www.selt.com → PRODUCTS → AUTOMATION
Environmental conditions of increased threat:
bathrooms and showers, kitchens, garages, cellars, saunas, rooms for domestic animals, operating theatres in hospitals,
pump rooms, heat exchange rooms, spaces limited by conducing areas, campsites, open spaces, etc. are regarded as
environments with increased threat conditions.