SELMI ROASTER CENTOVENTI Скачать руководство пользователя страница 1

 

 

 

 

 

 

ROASTER CENTOVENTI 

manuale d'uso e manutenzione 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание ROASTER CENTOVENTI

Страница 1: ...ROASTER CENTOVENTI manuale d uso e manutenzione...

Страница 2: ......

Страница 3: ...ne This document is an integral part of the ROASTER Centoventi roasting machine with fluidized bed as described in section 1 7 4 of annex I of directive 2006 42 CE The Italian edition of this manual c...

Страница 4: ...imitations 22 2 3 Safety symbols and plaques 23 2 4 Safety and protection devices 23 2 5 Client s safety measures 24 2 6 Personal protection equipment 24 2 7 Residual risks 25 2 8 Applied Directives 2...

Страница 5: ...tion necessary for the correct use and maintenance of the machine Consequently it is absolutely necessary to meticulously follow the instructions given in the manual during every phase of the machine...

Страница 6: ...6 1 5 EXTERNAL COMPONENTS 1 Exhaust system roasting area 2 Exhaust system of the cooling area 3 Product exit 4 Electrical power supply 1 2 2 3 4...

Страница 7: ...7 EXTERNAL COMPONENTS 1 Filters area 2 Skin collector 3 Side protection 4 Pipe for loading the product 5 Exhaust pipe roasting area 1 2 3 4 5...

Страница 8: ...8 1 6 BACK SIDE OF THE MACHINE WITHOUT THE PROTECTION 1 Exhaust system roasting area 2 Filters 3 Exhaust system of the cooling area 4 Skin collector 1 2 2 3 4...

Страница 9: ...control of the roasting chamber 3 Roasting chamber 4 Control panel 5 Cooling chamber 6 Blower for charging the product 7 Exhaust system roasting area 8 Sensor level 9 Roasting chamber lights 10 Emerg...

Страница 10: ...10 UPPER PART WITHOUT THE PROTECTION 1 Roasting chamber side blower 2 Electrical resistance for the side blower 3 Roasting chamber 1 1 2 2 1 2 3 1 2...

Страница 11: ...ting chamber bottom bloower 2 Electrical resistance bottom blower 3 Connection between the roasting and the cooling chamber 4 Cooling chamber 5 Compressed air supply 6 Manometer 7 Electrical valves gr...

Страница 12: ...12 DETAIL OF LEFT SIDE WITHOUT THE PROTECTION 1 Air temperature probe bottom 2 Electrical resistance 3 Pipe coming from the bottom blower 1 1 2 2 1 1 2 3 1 2...

Страница 13: ...13 DETAIL OF LEFT SIDE WITHOUT THE PROTECTION 1 Pipe to clean the roasting cone 1 1 2...

Страница 14: ...for the cooling chamber 2 Piston for the opening closing of the roasting chamber cone 3 Exit of the finish product 4 Cooling fan 5 Piston for unload the product 6 Exhaust pipe of the cooling chamber 7...

Страница 15: ...15 DETAIL OF UPPER PART WITHOUT THE PROTECTION 1 Heart product temperature probe 2 Air temperature probe side 3 Air compressed blow 1 3 2...

Страница 16: ...ectrical panel door security micro 3 Power board 4 Inverter 5 Heating elements relay 6 Inverter filter 7 General contactor 8 Security protection 9 Transformer 10 220 V Fuse protection 11 Ground connec...

Страница 17: ...an the cone 10 Solenoid pneumatic actions A Opening the roasting cone B Unload product C Air compressed blow 11 Fan cooling electrical panel 12 lights roasting chamber connection 13 Relay Heating resi...

Страница 18: ...ystem vertiflow patent which has a temperature sensor at the heart of the product It is particularly versatile for the roasting of coffee hazelnuts almonds pistachios and any other appropriate product...

Страница 19: ...er installed 22 kW Voltage supply 380V Number of phases 3 Frequency 50Hz or 60Hz Noise 80 dB Protection degree IP65 This data can change according to the contractual installation conditions For correc...

Страница 20: ...m and steel can be recycled in the appropriate collection centres According to the RoHS regulations electronic boards and electric material should be recycled separately in authorised collection centr...

Страница 21: ...otential adjustments etc He she can only carry out the specific tasks described in this manual reserved for this role Mechanical maintenance technician The technician is qualified to use the machine a...

Страница 22: ...Safety limitations Attention The indications mentioned hereafter cannot completely safeguard from all dangers that one might encounter while using the machine they must be used in conjunction with com...

Страница 23: ...N IMPLEMENTED IN OBSERVANCE OF PRESIDENTIAL DECREE 543 ON THE PREVENTION OF ACCIDENTS positioned on the door of the electrical panel Label indicating compulsory reading of the manual positioned on the...

Страница 24: ...ures The client must arrange for the following safety measures to be in places Provision of an adequate location for installation paying particular attention to the characteristics below Adequate floo...

Страница 25: ...ngerous to the people in the vicinity who are helping with the moving Risks of faults to the circuits of signalling safety protection and emergency stop In the case of a circuit fault the safety and s...

Страница 26: ...ect upright position of the packaging the second symbol shows that the packaging must be protected from the rain the third symbol shows that the content of the packaging is fragile and must be handled...

Страница 27: ...he rear wheels by lifting the back of the machine Very carefully lower the machine from the platform Note Keep the original packaging it may be necessary to use it if the machine needs to be sent to t...

Страница 28: ...ressed connection In the picture below is shown the position of the air connection plug Attention Make sure the pressure is around 2 bar The air compressed must be disoiled and disidratated air compre...

Страница 29: ...L PANEL The Roaster machine is equipped with a touch screen here there are the display pages 1 Home page Push on the Selmi roasting machines logo to go to the next page 2 Roasting mode page A Normal r...

Страница 30: ...e is the temperature read by the probe 7 Roasting Graphic On the X value there is the temperature and on the Y value there is the time 8 Roasting time 9 Unload final product You can set the time for u...

Страница 31: ...hat the unloading product countdown 10 Temperature it s shown in real time the temperature of the roasting chamber heart 11 Unload final product You can set the time for unload the finish product 12 R...

Страница 32: ...THE MACHINE 1 Be sure to have the air compressed and electricity connected 2 Load the product aspirating it as the images below 3 Be sure to have a bowl under the final product exit on the right side...

Страница 33: ...e also a button function This means that holding the button you go directly to the cooling process This is an emergency skip in case the roasting cycle programmed is too long or wrong KEYBOARD Orange...

Страница 34: ...TED SETTINGS FOR ROASTER PRODUCT FAN AIR TEMP TEMP PROD 1 Light hazelnuts 90 220 240 C 165 C 2 Medium Roasted Hazelnut 90 220 240 C 173 C 3 Dark Hazelnut 90 220 240 C 185 C 4 Skinned Light Almond 90 2...

Страница 35: ...RM COOLING The fridge is absorbing more than the limit set into the parameters ALARM STIRRER Only roaster centosei and centoventi ALARM ASPIRATOR Only roaster centoventi MAINTENANCE CHANGE FILTERS CON...

Страница 36: ...ording to the laws in force concerning waste materials If necessary they can be sent to the manufacturer who will dispose of them in the most appropriate manner 6 2 General safety practice Attention B...

Страница 37: ...ons in section 6 3 Attention Following every maintenance intervention it is the Safety Officer duty to ascertain that the machine is working properly and that all the safety devices are present and fu...

Страница 38: ...of the roasting chamber ATTENTION do this operation when the machine is cold Every Week Clean the roasting chamber from the possible skin that can remain inside Open the big bolt that close the cover...

Страница 39: ...39 ELECTRICAL SCHEDULE...

Страница 40: ...40...

Страница 41: ...41...

Страница 42: ...42...

Страница 43: ...43...

Страница 44: ...44...

Страница 45: ...45...

Страница 46: ...46...

Страница 47: ...47...

Страница 48: ...General contactor RST120 007 Transformer 220 V 24 V RST120 008 Security protection RST120 009 Inverter RST120 010 Filter inverter RST120 011 220V Fuse protection RST120 012 Electrical panel Cooling f...

Страница 49: ...tor RST120 025 Cooling mixer reducer RST120 026 Electrical resistance for the bottom blower RST120 027 Electrical resistance for the side blower RST120 028 Manometer RST120 029 Electrovalves RST120 03...

Страница 50: ...50 RST120 037 blower flexible pipe RST120 038 Air compressed connection plug RST120 039 Air compressed pipe connections...