31
Ausgabe
issue
D / 04.02.2013
Dokument
document
OM.SCT.02e
Blatt
sheet
9 (18)
9
Dismantling/reassembly
9.1.3 Pump - dismantling - SCT
9.1.3.1 Preparing the pump for dismantling
9.1.3.2 Stator (601) - Dismantling
WARNING
Risk of pump tipping or falling.
Death or serious injury can occur.
Fasten the base plate (GPU) to secure the
pump.
DANGER
Dangerous voltage.
Death or serious injury can occur.
Note safety regulations.
Disconnect pump from all sources of energy.
Secure electrical connections against restarting.
Allow pipelines to cool.
See chapter 6 of the operating and assembly instructions for instructions regarding de-
commissioning.
No space needs to be left for stator removal when dismantling/reassembling the stator and
rotor.
Pump with dry-running protection option
(TSE)
•
The holding device for the dry running pro-
tection (TSE) can get in the way when dis-
mantling the adjusting segments (635).
•
If this is the case, remove the holding de-
vice (657) and the self-tapping screws
(658).
Remove upper adjusting segments
(635.o).
–
Conveying product can escape.
Pump with dry-running protection option
(TSE)
Mount self-tapping screws (658) and hold-
ing device (657).