30
Ausgabe
issue
D / 04.02.2013
Dokument
document
OM.SCT.02e
Blatt
sheet
8 (18)
9
Dismantling/reassembly
Fine adjustment of the pump parameters:
Fine adjustments for the pump parameters can be made by evenly adjusting the nuts at the
adjusting segments (635).
•
+10° = increases clamping.
•
-10° = reduces clamping.
Observe the order.
–
1-1’, 2-2’, 3-3’, 4-4’
NOTICE
Motor overload
Damage to property can occur.
Do not exceed motor's maximum power consumption.