Edge
Smart Keypads and Card Readers
Direct Programming Manual
If you need help, please email
or call
(972) 474-6390
.
67
Note: Enabling anti-passback while split-relay functionality is enabled may cause some
undesirable effects.
Note: The procedures involving Wiegand inputs will not work if the Wiegand inputs involved
are disabled.
Disable Anti-Passback
This procedure will disable anti-passback.
1251
$
6
$
310
$
0
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter next sub mode 310 and listen for good tone.
Enter next sub mode 0 and listen for good tone.
Enter # key to exit Programming Mode.
Enable Timed Lockout for Relay A
This procedure will configure a timed lockout for Relay A after each use.
1251
$
6
$
310
$
1
$
XXX
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter next sub mode 310 and listen for good tone.
Enter next sub mode 1 and listen for good tone.
Enter anti-passback time in seconds (001 to 999) and listen for good tone.
Enter # key to exit Programming Mode.
Enable Timed Lockout for Relay B
This procedure will configure a timed lockout for Relay B after each use.
1251
$
6
$
310
$
2
$
XXX
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 6 and listen for good tone.
Enter next sub mode 310 and listen for good tone.
Enter next sub mode 2 and listen for good tone.
Enter anti-passback time in seconds (001 to 999) and listen for good tone.
Enter # key to exit Programming Mode.
Enable Scheme A (K
$
W1 or W2)
This procedure will enable Scheme A, in which access must first be granted by the Edge unit