Mode 3
This mode is a combination of Modes 1 and 2.
1251
$
4
$
9
$
3
$
X
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 4 and listen for good tone.
Enter secondary sub mode 9 and listen for status tones:
Good tone:
Event Input 1 is disabled (Mode 0).
One tone:
Mode 1 enabled.
Two tones:
Mode 2 enabled.
Three tones: Mode 3 enabled.
Four tones:
Mode 4 enabled.
Five tones:
Mode 5 enabled.
Enter 3 for Mode 3 and listen for good tone.
Enter 1 (for Relay A) or 2 (for Relay B) and listen for good tone.
Enter # key to exit Programming Mode.
Mode 4
When this mode is active, the selected relay will be enabled when the state of Event Input 1
changes from normally open (N/O) to normally closed (N/C). Otherwise the relay is disabled.
1251
$
4
$
9
$
4
$
X
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 4 and listen for good tone.
Enter secondary sub mode 9 and listen for status tones:
Good tone:
Event Input 1 is disabled (Mode 0).
One tone:
Mode 1 enabled.
Two tones:
Mode 2 enabled.
Three tones: Mode 3 enabled.
Four tones:
Mode 4 enabled.
Five tones:
Mode 5 enabled.
Enter 4 for Mode 4 and listen for good tone.
Enter 1 (for Relay A) or 2 (for Relay B) and listen for good tone.
Enter # key to exit Programming Mode.
Mode 5
When this mode is active, the selected relay will be triggered or latched when the state of Event
Input 1 changes from normally closed (N/C) to normally open (N/O).